![National Instruments VXI-MXI User Manual Download Page 108](http://html1.mh-extra.com/html/national-instruments/vxi-mxi/vxi-mxi_user-manual_3577100108.webp)
Register Descriptions
Chapter 4
VXI-MXI User Manual
4-50
© National Instruments Corporation
Trigger Synchronous Acknowledge Register
VXIbus Address:
Base A 34 (hex)
Attributes:
Write Only
W
15
14
13
12
11
10
9
X
X
X
X
X
X
X
X
8
W
7
6
5
4
3
2
1
X
X
X
X
X
X
X
X
0
Writing any value to this register reinitializes the SSINT* bit in the Trigger Mode Selection
Register.
Trigger Asynchronous Acknowledge Register
VXIbus Address:
Base A 36 (hex)
Attributes:
Write Only
W
15
14
13
12
11
10
9
X
X
X
X
X
X
X
X
8
W
7
6
5
4
3
2
1
X
X
X
X
X
X
X
X
0
Writing any value to this register reinitializes the ASINT* bit in the Trigger Mode Selection
Register.