Figure C-4 shows the default settings for the CLK10 switches. This
configuration is as follows:
•
CLK10 is generated from the onboard oscillator (S6).
•
The CLK10 signal is not terminated (S2).
•
The VXI-1394 receives the external CLK10 signal (S3).
•
The polarity of the CLK10 signal (S4) is irrelevant when the VXI-1394
receives the external CLK10 signal. However, it is configured to be
inverted when the CLK10 SMB is used as output.