Configuring Multiple Devices with USB

You can connect multiple devices in the following ways:

Multiple USB 2.0 or 3.0 interfaces—One device for each interface

Single USB 2.0 or 3.0 interface—Multiple devices connected to a USB 2.0 or 3.0 hub

Tip

 

Sharing a single USB 2.0 or 3.0 controller interface on your host computer

among multiple devices may reduce overall signal throughput. For maximum signal
throughput, NI recommends that you connect no more than one device per USB
interface.

To configure multiple devices connected to either separate USB 2.0 or 3.0 interfaces or to a
USB hub, assign a different device ID to each USRP device. Because each NI 290x device has
the same default device ID, you must change the device ID for each USRP device before you
connect an additional device to the host computer.

Programming the NI 2900/2901

NI-USRP Instrument Driver

NI-USRP features a set of VIs and properties that exercise the functionality of the NI 290x,
including configuration, control, and other device-specific functions. Refer to the

NI-USRP Help

 for information about using the instrument driver in your applications.

Using Examples

The instrument driver examples are instructional tools that demonstrate some of the
functionality of USRP devices. You can use these examples separately or integrate them into
your systems.

Access the examples from within LabVIEW Communications System Design software by
selecting 

File

»

Examples

.

Troubleshooting

If an issue persists after you complete a troubleshooting procedure, contact NI technical
support or visit 

ni.com/support

.

Why Doesn't the USRP Device Appear in MAX?

MAX does not support NI 290x devices. Use the NI-USRP Configuration Utility instead.
Open the NI-USRP Configuration Utility from the Start menu at 

Start

»

All Programs

»

National Instruments

»

NI-USRP

»

NI-USRP Configuration Utility

.

8

  | 

ni.com

  | 

NI USRP-2900/2901 Getting Started Guide

Summary of Contents for USRP-2900

Page 1: ...oubleshooting 8 Why Doesn t the USRP Device Appear in MAX 8 Why Doesn t the USRP Device Appear in the NI USRP Configuration Utility 9 Front Panels and Connectors 9 Direct Connections to the NI 290x 9...

Page 2: ...e that you are in compliance with all local laws before operating this product with an antenna Verifying the System Requirements To use the NI USRP instrument driver your system must meet certain requ...

Page 3: ...1 or RX2 of each receiving USRP device Note The driver software media installs the NI USRP driver software and electronic documentation including the NI USRP Help the NI USRP Readme and device specifi...

Page 4: ...Electrostatic Discharge ESD on the connector pins of any I O port To prevent damage industry standard ESD prevention measures must be employed during installation maintenance and operation Caution Do...

Page 5: ...are and NI USRP before you install the hardware Note The NI 2900 2901 device connects to a host computer using a standard USB connector and USB cable 1 Power on the computer 2 Attach the antenna or ca...

Page 6: ...e of the tab similar to the following figure Figure 1 Confirming USB Connection Note If your device is not listed verify that your device is powered on and correctly connected then click the Refresh D...

Page 7: ...spaces or special characters The utility should appear similar to the following figure Figure 2 Changing the Device ID 6 Click the Change Device ID button or press Enter to change the device ID 7 The...

Page 8: ...SRP Instrument Driver NI USRP features a set of VIs and properties that exercise the functionality of the NI 290x including configuration control and other device specific functions Refer to the NI US...

Page 9: ...ctions to the NI 290x to avoid damaging the device Caution Apply external signals only while the NI 290x is powered on Applying external signals while the device is powered off may cause damage Ensure...

Page 10: ...NI USRP 2900 Module LEDs LED Description Color Indication RF 0 RX2 Indicates the receive status of the device Off The device is not active Green The device is receiving data TX1 RX1 Indicates the tran...

Page 11: ...power connector NI USRP 2901 Connectors and LEDs Figure 5 NI USRP 2901 Front Panel NI USRP 2901 70 MHz 6 GHz ESD SENSITIVE RF 0 TX1 RX1 RX2 RF 1 TX1 RX1 RX2 Designed by Ettus Research TX OUTPUT MAX 20...

Page 12: ...device is not active Green The device is receiving data RF 1 RX2 Indicates the receive status of the device Off The device is not active Green The device is receiving data TX1 RX1 Indicates the trans...

Page 13: ...Services repairs extended warranty and other services Visit ni com register to register your National Instruments product Product registration facilitates technical support and ensures that you receiv...

Page 14: ...and third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the National Instruments global trade compliance p...

Reviews: