NI USB-9265 User Guide and Specifications
12
ni.com
Wiring for High-Vibration Applications
If an application is subject to high vibration, National Instruments
recommends that you either use ferrules to terminate wires to the
detachable screw-terminal connector or use the NI 9932 backshell kit to
protect the connections. Refer to Figure 9 for an illustration of using
ferrules. Refer to Figure 3 for an illustration of the NI 9932 connector
backshell.
Figure 9.
10-Terminal Detachable Screw-Terminal Connector with Ferrule
Specifications
The following specifications are typical for the range –40 to 70 °C unless
otherwise noted. All voltages are relative to COM unless otherwise noted.
Output Characteristics
Number of channels................................4 analog output channels
DAC resolution.......................................16 bits
Type of DAC ..........................................String
Power-on output state .............................0
Startup current ........................................0.0 mA
Power-down current ...............................0.0 mA
Full-scale output current
Minimum .........................................20.1 mA
Typical.............................................20.6 mA
Maximum ........................................21.0 mA