SCXI-1351 One-Slot Cable Extender

2

ni.com

Conventions

The following conventions are used in this guide:

»

The

»

symbol leads you through nested menu items and dialog box options

to a final action. The sequence

File»Page Setup»Options

directs you to

pull down the

File

menu, select the

Page Setup

item, and select

Options

from the last dialog box.

This icon denotes a note, which alerts you to important information.

italic

Italic text denotes variables, emphasis, a cross reference, or an introduction
to a key concept. This font also denotes text that is a placeholder for a word
or value that you must supply.

monospace

Text in this font denotes text or characters that you should enter from the
keyboard, sections of code, programming examples, and syntax examples.
This font is also used for the proper names of disk drives, paths, directories,
programs, subprograms, subroutines, device names, functions, operations,
variables, filenames and extensions, and code excerpts.

Safety Information

The following section contains important safety information that you

must

follow when installing and using the product.

Do

not

operate the product in a manner not specified in this document.

Misuse of the product can result in a hazard. You can compromise the
safety protection built into the product if the product is damaged in any
way. If the product is damaged, return it to NI for repair.

Do

not

substitute parts or modify the product except as described in this

document. Use the product only with the chassis, modules, accessories, and
cables specified in the installation instructions. You

must

have all covers

and filler panels installed during operation of the product.

Do

not

operate the product in an explosive atmosphere or where there may

be flammable gases or fumes. Operate the product only at or below the
pollution degree stated in the

Specifications

section. Pollution is foreign

matter in a solid, liquid, or gaseous state that can reduce dielectric strength
or surface resistivity. The following is a description of pollution degrees:

Pollution degree 1 means no pollution or only dry, nonconductive
pollution occurs. The pollution has no influence.

Pollution degree 2 means that only nonconductive pollution occurs in
most cases. Occasionally, however, a temporary conductivity caused
by condensation must be expected.

Summary of Contents for SCXI-1351

Page 1: ...uments SCXI 1351 one slot cable extender in an SCXI system The SCXI 1351 extends the pinout from a 100 or 50 pin digital I O DIO data acquisition DAQ device to one or more SCXI modules The SCXI 1351 is intended for use with the SCXI 1181 module for custom signal conditioning but you can use it with some other SCXI modules What You Need To Get Started To set up and use the SCXI 1351 you need the fo...

Page 2: ...follow when installing and using the product Do not operate the product in a manner not specified in this document Misuse of the product can result in a hazard You can compromise the safety protection built into the product if the product is damaged in any way If the product is damaged return it to NI for repair Do not substitute parts or modify the product except as described in this document Use...

Page 3: ... connecting them to or disconnecting them from the product Operate this product only at or below the installation category stated in the Specifications section The installation category for this device installation category I is for measurements performed on circuits not directly connected to MAINS1 This category is a signal level such as voltages on a printed wire board PWB on the secondary of an...

Page 4: ...racket connector a female rear connector and a male breakout connector Figure 1 shows the SCXI 1351 with the cable extended and the SCXI 1351 with the cable folded into place and ready for installation Figure 1 SCXI 1351 Extended and Folded Views 1 Female Rear Connector 2 Male Breakout Connector 3 Mounting Bracket Connector 4 Mounting Bracket 2 3 1 4 1 2 4 3 ...

Page 5: ... The NB1 and R5050 cables have two 50 pin connectors Table 1 shows which cable connector you should use to connect to the SCXI 1351 Note If the module that you are using is not listed in this table please refer to the NI Web site at ni com support for technical support Table 1 Cabling Options Module Type SCXI Module 100 Pin 50 Pin Relay SCXI 1160 Positions 1 50 Positions 1 50 SCXI 1161 Positions 1...

Page 6: ...the type of DIO device SCXI modules and operation mode you use Refer to Figure 2 for the basic installation procedure Specific installation procedures follow Figure 2 Figure 2 SCXI 1351 Installation 1 SCXI Module Rear Signal Connector 2 Mounting Bracket Connector 3 Mounting Bracket 4 Female Rear Connector 5 Male Breakout Connector FUSE PULL 1 2 3 5 4 ...

Page 7: ...o the DIO device Note Leave the female rear connector without a connection Installing the SCXI 1351 with a 100 Pin DIO Device in Parallel Mode Perform the following steps to install the SCXI 1351 with a 100 pin DIO device in parallel mode 1 Power off the computer and SCXI chassis 2 Install the two SCXI modules following the instructions in the module user manual 3 Connect the male breakout connect...

Page 8: ... following steps to install the SCXI 1351 with multiple SCXI 1181 modules Refer to Figure 3 for an illustration of this installation procedure 1 Power off the computer and SCXI chassis 2 With the front of the chassis facing you install the SCXI 1181 modules in adjacent slots starting on the right following the instructions in the module user manual 3 Connect the male breakout connector of the SCXI...

Page 9: ...t most module 8 If you have a 100 pin DIO device connect the 100 pin cable connector to the device If you have a 50 pin DIO device connect the remaining 50 pin cable connector to the device Figure 3 Multiple SCXI 1351 Connection 1 Female Rear Connector 2 Male Breakout Connector 3 Mounting Bracket Connector 4 Female Rear Connector to SCXI 1181 Module 1 3 2 1 3 2 4 3 2 ...

Page 10: ...C installation category I Environmental Operating temperature 0 to 50 C Storage temperature 20 to 70 C Humidity 10 to 90 RH noncondensing Maximum altitude 2000 meters Pollution degree indoor use only 2 Safety The SCXI 1351 meets the requirements of the following standards for safety and electrical equipment for measurement control and laboratory use EN 61010 1 1993 A2 1995 IEC 61010 1 1990 A2 1995...

Page 11: ...swers you need contact your local office or NI corporate For telephone support in the United States dial 512 795 8248 For telephone support outside the United States contact your local branch office Australia 03 9879 5166 Austria 0662 45 79 90 0 Belgium 02 757 00 20 Brazil 011 3262 3599 Canada Calgary 403 274 9391 Canada Montreal 514 288 5722 Canada Ottawa 613 233 5949 Canada Québec 514 694 8521 C...