background image

SCXI-1327 Installation Guide

14

ni.com

Technical Support Resources

NI Web Support

National Instruments Web support is your first stop for help in solving
installation, configuration, and application problems and questions. Online
problem-solving and diagnostic resources include frequently asked
questions, knowledge bases, product-specific troubleshooting wizards,
manuals, drivers, software updates, and more. Web support is available
through the Technical Support section of

ni.com

Worldwide Support

National Instruments has offices located around the world to help address
your support needs. You can access our branch office Web sites from the
Worldwide Offices section of

ni.com

Branch office Web sites provide

up-to-date contact information, support phone numbers, e-mail addresses,
and current events.

If you have searched the technical support resources on our Web site
and still cannot find the answers you need, contact your local office or
National Instruments corporate. For telephone support in the United States,
dial 512 795 8248. For telephone support outside the United States, contact
your local branch office:

Australia 03 9879 5166, Austria 0662 45 79 90 0, Belgium 02 757 00 20,
Brazil 011 284 5011, Canada (Calgary) 403 274 9391,
Canada (Ontario) 905 785 0085, Canada (Québec) 514 694 8521,
China 0755 3904939, Denmark 45 76 26 00, Finland 09 725 725 11,
France 01 48 14 24 24, Germany 089 741 31 30, Greece 30 1 42 96 427,
Hong Kong 2645 3186, India 91805275406,
Israel 03 6120092, Italy 02 413091, Japan 03 5472 2970,
Korea 02 596 7456, Mexico (D.F.) 5 280 7625,
Mexico (Monterrey) 8 357 7695, Netherlands 0348 433466,
New Zealand 09 914 0488, Norway 32 27 73 00, Poland 0 22 528 94 06,
Portugal 351 1 726 9011, Singapore 2265886, Spain 91 640 0085,
Sweden 08 587 895 00, Switzerland 056 200 51 51,
Taiwan 02 2528 7227, United Kingdom 01635 523545

Summary of Contents for SCXI-1327

Page 1: ...XI 1327 channel has a precision 100 1 resistive voltage divider that you can use to measure voltages of up to 300 Vrms or 300 VDC with the SCXI 1120 SCXI 1120D SCXI 1121 SCXI 1125 or SCXI 1126 You can...

Page 2: ...ic text denotes variables emphasis a cross reference or an introduction to a key concept This font also denotes text that is a placeholder for a word or value that you must supply monospace Text in th...

Page 3: ...n become impaired if the device becomes damaged in any way If the device is damaged turn the device off and do not use it until service trained personnel can check its safety If necessary return the d...

Page 4: ...ational Instruments is not liable for any damages or injuries resulting from inadequate safety earth ground connections Do not loosen or re orient the safety ground lug hardware when connecting the sa...

Page 5: ...nnect the signal to the terminal block perform the following steps referring to Figures 1 and 2 as necessary 1 Unscrew the top cover screws and remove the top cover 2 Loosen the strain relief screws a...

Page 6: ...ning You can add insulation or padding if necessary Note When connecting your signals to the SCXI 1327 follow the labeling on the SCXI 1327 for the appropriate module as indicated in Figure 2 1 Top Co...

Page 7: ...5 7 in lb 8 Connect the safety earth ground to the safety ground lug Refer to the Safety Information section for connection information 9 Reinstall the strain relief bar and tighten the strain relief...

Page 8: ...rushing off light dust with a soft nonmetallic brush Remove other contaminants with deionized water and a stiff nonmetallic brush The unit must be completely dry and free from contaminants before retu...

Page 9: ...r 100 1 setting Attenuation ratio temperature drift 15 ppm C Resistance between CH and CH terminals 1 1 attenuation setting Determined by attached module 100 1 attenuation setting 1 M Coupling DC only...

Page 10: ...mponents None Safety earth ground lugs 1 Strain relief Strain relief bar at terminal block entrance Mechanical Dimensions 17 8 by 7 94 by 3 0 cm 7 0 by 3 125 by 1 2 in Weight 200 g 7 oz Environmental...

Page 11: ...to 50 C Converting a Thermistor Voltage to a Temperature National Instruments software can convert a thermistor voltage to the thermistor temperature for the circuit diagram shown in Figure 3 In LabVI...

Page 12: ...to the SCXI 1327 For more information about channel string arrays and the SCXI channel addressing syntax see the LabVIEW Measurements Manual Note This section is not applicable to the SCXI 1126 With...

Page 13: ...ead this section to operate the SCXI 1327 The circuit diagram in Figure 3 is optional information that you can use if you want more details about the SCXI 1327 temperature sensor Figure 3 Temperature...

Page 14: ...e searched the technical support resources on our Web site and still cannot find the answers you need contact your local office or National Instruments corporate For telephone support in the United St...

Page 15: ......

Reviews: