NI SCXI-1366 Installation Guide

Figure 2.  

SCXI-1366 Terminal Block Signal Connections

62 POSITION DSUB CONNECT

OR

62 POSITION DSUB CONNECT

OR

0-3.3 V TRIGGERING

USE SHIELDED COAX CABLE

5.5 V MAX

CH 0

CH 1

CH 2

CH 3

CH 4

CH 5

CH 6

CH 7

N
O

C
O
M

C
O
M

N
O

N
C

C
O
M

N
O

N
C

C
O
M

N
O

N
C

N
O

N
C

N
O

C
O
M

N
C

O

N

N
C

C
O
M

N
O

N
C

C
O
M

N
C

C
O
M

C

N

CH 23

N
O

150 VDC / 125 VRMS MAX          5 A MAX

150 VDC / 125 VRMS MAX          5 A MAX

150 VDC / 125 VRMS MAX          5 A MAX

N
C

CH 15

CH 25

CH 26

CH 27

CH 28

CH 29

CH 30

CH 24

O

C

M

CH 19

M

O

C

CH 11

C

M

O

CH 9

C

N

C

N

N

CH 8

M

O

C

M

O

C

O

N

N

C

N

N

CH 10

M

O

C

O

C

O

CH 17

CH 16

C

N

M

O

C

N
O

M

O

C

O

N

C

N

O
M

C

C

N

O
M

C

O

N

CH 18

N
C

N
O

M

O

C

C

N

O

N

C

N

O

C

M

O

N

C

N

O

N

CH 13

N

N

C

N

N

CH 12

C

O

C

M

O

O

N

C

N

C

N

CH 14

O

M

O

C

O

M

O

CH 21

CH 20

O

N

C

N

N
O

N
C

M

C
O

C

N

O

N

C

N

O

N

O
M

C

CH 22

O

N

M

O

C

N
C

M

O

C

C

N

C

N

O
M

C

O

N

O

C

M

O

N

TRIG IN

TRIG OUT

GND

GND

CH 31

N

C

O

M

O

M

O

C

N
C

O

C

M

O

N

Summary of Contents for SCXI-1166

Page 1: ...SCXI 1166...

Page 2: ...d intended to carry signal voltages no greater than 150 V This module can withstand up to 800 V impulse voltage Do not use this module for connection to signals or for measurements within Categories I...

Page 3: ...of connectors Ground yourself using a grounding strap or by holding a grounded object Touch the antistatic package to a metal part of the chassis before you remove the terminal block from the package...

Page 4: ...leaving plenty of space for the signal cables 4 Pull the signal cables at least one foot through the strain relief opening shown in Figure 1 5 Connect the safety earth ground to the safety ground lug...

Page 5: ...i com Figure 1 SCXI 1366 Terminal Block 1 Strain Relief Opening 2 Safety Ground Lug 3 Strain Relief Bar 4 Terminal Block Top Cover 5 Screw Terminals 6 Rear Connector 7 Thumbscrews 8 10 32 3 4 Inch Scr...

Page 6: ...H 23 N O 150 VDC 125 VRMS MAX 5 A MAX 150 VDC 125 VRMS MAX 5 A MAX 150 VDC 125 VRMS MAX 5 A MAX N C CH 15 CH 25 CH 26 CH 27 CH 28 CH 29 CH 30 CH 24 O C M CH 19 M O C CH 11 C M O CH 9 C N C N N CH 8 M...

Page 7: ...e following steps 1 Connect the terminal block front connectors to its mating connectors on the terminal block 2 Tighten the top and bottom thumbscrews on the back of the terminal block rear panel to...

Page 8: ...55011 Class A at 10 m FCC Part 15A above 1 GHz Immunity EN 61326 1997 A2 2001 Table 1 EMC EMI CE C Tick and FCC Part 15 Class A Compliant Note For EMC compliance you must operate this device with shie...