National Instruments SCC-FT01 User Manual Download Page 2

SCC-FT01 Feedthrough Module User Guide

2

ni.com

italic

Italic text denotes variables, emphasis, a cross reference, a hardware label, 
or an introduction to a key concept. This font also denotes text that is a 
placeholder for a word or value that you must supply.

monospace

Text in this font denotes text or characters that you should enter from the 
keyboard, sections of code, programming examples, and syntax examples. 
This font is also used for the proper names of disk drives, paths, directories, 
programs, subprograms, subroutines, device names, functions, operations, 
variables, filenames, and extensions.

SC-2345

SC-2345 refers to both the SC-2345 connector block and the SC-2345 with 
configurable connectors.

SCC

SCC refers to any SCC series signal conditioning module.

What You Need to Get Started

To set up and use the SCC-FT01, you need the following items:

SC-2345/2350 with one of the following:

SCC-PWR01

SCC-PWR02 and the PS01 power supply

SCC-PWR03 (requires a 7 to 42 VDC power supply, not included)

One or more SCC-FT01 modules

SCC-FT01 Feedthrough Module User Guide

SC-2345/2350 User Manual

, available at 

ni.com

SCC Quick Start Guide

, available at 

ni.com

Read Me First: Safety and Radio-Frequency Interference

SC-2345 Quick Reference Label

68-pin E Series DAQ device, documentation, and 68-pin cable of 
1 or 2 m length

1/8 in. flathead screwdriver

Numbers 1 and 2 Phillips screwdrivers

Summary of Contents for SCC-FT01

Page 1: ...l action The sequence File Page Setup Options directs you to pull down the File menu select the Page Setup item and select Options from the last dialog box This icon denotes a note which alerts you to...

Page 2: ...ions SC 2345 SC 2345 refers to both the SC 2345 connector block and the SC 2345 with configurable connectors SCC SCC refers to any SCC series signal conditioning module What You Need to Get Started To...

Page 3: ...gnal wires Caution If you plug the unmodified SCC FT01 into any SCC socket other than single stage AI sockets J1 through J8 or AO sockets J17 and J18 you can damage the E Series DAQ device You can plu...

Page 4: ...nformation on AI modes refer to the SC 2345 User Manual For information on AI configuration modes refer to the DAQ device documentation When you plug the SCC FT01 into an AO SCC socket the following c...

Page 5: ...NRSE mode Refer to the Measurement Automation Explorer Help for more information and instructions on configuring channels For more information about configuring the SCC FT01 using NI DAQmx refer to t...

Page 6: ...5 Figure 1 SCC FT01 Parts Locator Diagram Table 2 shows the signals available for circuit design when you plug the SCC FT01 into each type of SCC socket on the SC 2345 The pad numbers correspond to th...

Page 7: ...GND 5 V AO GND B N A or AI Cascaded REF1 PFI 1 AI REF TRIG or AI Cascaded REF1 4 PFI 7 AI SAMPLE C LK or P0 X 2 15 V AO GND A FREQ OUT FREQ OUT 5 AI GND 15 V and REF 5 V J17 AO 0 J18 AO 1 PFI 5 AO SA...

Page 8: ...ration Figure 2c illustrates single stage AI configuration Analog Input and Digital Input Output To use the SCC FT01 for AI or digital signal conditioning use the pads above connector J2 labeled AI P0...

Page 9: ...he SCC FT01 into any AO socket on the SC 2345 The AO 0 and AO 1 signals depend on which AO SCC socket you use If you plug the SCC FT01 into the AO SCC socket J17 the DAC A pad connects to AO 0 and the...

Page 10: ...ick Start Guide Specifications These ratings are typical at 25 C unless otherwise stated Analog Number of input channels 1 DIFF or 2 SE when plugged into an AI socket on the SC 2345 Number of output c...

Page 11: ...rtification column Electromagnetic Compatibility Emissions EN 55011 Class A at 10 m FCC Part 15A above 1 GHz Immunity EN 61326 1997 A2 2001 Table 1 CE C Tick and FCC Part 15 Class A Compliant Note For...