background image

INSTALLATION INSTRUCTIONS

NI sbRIO-9691/9692 Stacking Kit

The National Instruments sbRIO-9691 and sbRIO-9692 stacking kits are 
accessories you can use to stack NI 9

XXX

E board-only C Series modules 

under the sbRIO-960

X

/961

X

/963

X

/964

X.

 The sbRIO-9691 sheet metal 

(part number 195391

X

-01) is for installation with an sbRIO-960

X

 board; 

and the sbRIO-9692 sheet metal (part number196470

X

-01) is for 

installation with an sbRIO-961

X

/963

X

/964

board. The sheet metal frames 

are labeled with the part number. Throughout this document, the 
sbRIO-9691 and the sbRIO-9692 are referred to inclusively as the 
sbRIO-9691/9692.

Note

You need an M3 Phillips screwdriver to install the sbRIO-9691/9692 stacking kit.

The sbRIO-9691/9692 stacking kit contains the following components:

 

1

sbRIO-9691 Sheet Metal Frame OR

2

sbRIO-9692 Sheet Metal Frame

3

sbRIO-969

Riser Card

4

M3x5 Screw (Qty. 19 or 22)

OR

1

2

4

3

Summary of Contents for sbRIO-9691

Page 1: ...O 9692 sheet metal part number196470X 01 is for installation with an sbRIO 961X 963X 964X board The sheet metal frames are labeled with the part number Throughout this document the sbRIO 9691 and the...

Page 2: ...se Hazardous voltages may be present Caution Follow proper ESD precautions to ensure you are grounded before installing hardware Installing the Stacking Kit Complete the following steps to install the...

Page 3: ...ews to attachthesbRIO 960X 961X 963X 964X to the sbRIO 969X sheet metal frame as shown in Figure 1 Note Do not overtighten screws You may need to adjust the screws when assembly is complete Figure 1 C...

Page 4: ...64X and fasten three M3x5 screws into the sbRIO 9691 9692 sheet metal frame as shown in Figure 2 Figure2 PluggingthesbRIO 969XRiserCardintothesbRIO 960X 961X 963X 964X and sbRIO 9691 9692 Sheet Metal...

Page 5: ...iser card as shown in Figure 3 Caution Do not damage the back side of the module when plugging it in to the riser card Figure 3 Plugging the NI 9XXXE Board Only Module into the sbRIO 969X Riser Card 1...

Page 6: ...ule Figure 4 Fastening the NI 9XXXE Board Only C Series Module to the sbRIO 9691 9692 Sheet Metal Frame Specifications Sheet metal frame dimensions sbRIO 9691 23 6 10 7 2 0 cm 9 3 4 2 0 8 in sbRIO 969...

Page 7: ...llution degree 2 Environmental Management National Instruments is committed to designing and manufacturing products in an environmentally responsible manner NI recognizes that eliminating certain haza...

Page 8: ...d to help address your support needs For telephone support in the United States create your service request at ni com support and follow the calling instructions or dial 512 795 8248 For telephone sup...

Reviews: