background image

Worldwide Support and Services

The NI website is your complete resource for technical support. At 

ni.com/support

, you have

access to everything from troubleshooting and application development self-help resources to
email and phone assistance from NI Application Engineers.

Visit 

ni.com/services

 for information about the services NI offers.

Visit 

ni.com/register

 to register your NI product. Product registration facilitates technical

support and ensures that you receive important information updates from NI.

A Declaration of Conformity (DoC) is our claim of compliance with the Council of the
European Communities using the manufacturer’s declaration of conformity. This system
affords the user protection for electromagnetic compatibility (EMC) and product safety. You
can obtain the DoC for your product by visiting 

ni.com/certification

. If your product supports

calibration, you can obtain the calibration certificate for your product at 

ni.com/calibration

.

NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas,
78759-3504. NI also has offices located around the world. For support in the United States,
create your service request at 

ni.com/support

 or dial 1 866 ASK MYNI (275 6964). For

support outside the United States, visit the 

Worldwide Offices

 section of 

ni.com/niglobal

 to

access the branch office websites, which provide up-to-date contact information.

sbRIO-9687 Getting Started Guide

  | 

© National Instruments

  | 

17

Summary of Contents for sbRIO-9687

Page 1: ...necting the sbRIO 9687 13 Connecting the Power 13 Powering on the sbRIO 9687 14 Connecting the sbRIO 9607 to the Host Computer 14 Troubleshooting 14 Where to Go Next 16 Related Documentation 16 Worldw...

Page 2: ...AI s common ground is short circuited to the main ground on the sbRIO 9687 interface board when assembled defeating the channel to common isolation ratings of these circuits Unpacking the Kit Caution...

Page 3: ...rews M3 43 36 mm M F 4 5 mm Hex M3 5 mm panhead screws1 QTY 4 Standoffs RMC to Panel M3 29 81 mm M F 4 5 mm Hex no screws QTY 4 Standoffs and screws M3 11 12 mm M F 4 5 mm Hex M3 5 mm panhead screws1...

Page 4: ...6 1 Power connector 2 Inverter connectors 3 Thermistor connector 4 Display RS232 connector 5 Display power connector 6 AO breakout connector 7 AI connectors 8 RS232 input 9 Expansion board connectors...

Page 5: ...n 218 44 mm 8 600 in 269 24 mm 10 600 in 274 32 mm 10 800 in 105 66 mm 4 160 in 100 58 mm 3 960 in 12 7 mm 0 500 in 0 0 mm 0 00 in 28 85 mm 1 136 in 140 82 mm 5 544 in 169 67 mm 6 680 in 182 37 mm 7 1...

Page 6: ...Mounting the Hardware Before you mount the sbRIO 9687 the thermal kit sbRIO 9607 controller and sbRIO 9683 or sbRIO 9684 GPIC must be mounted to a thermally conductive surface at least 3 mm thick The...

Page 7: ...f the heat spreader b Align the heat spreader with the tapped holes for the sbRIO 9607 Refer to Figure 5 Installing the sbRIO 9607 for orientation c Fasten the four M3 16 mm M F standoffs through the...

Page 8: ...stall the sbRIO 9683 or sbRIO 9684 mezzanine board 1 Install the M3 29 81 mm M F standoffs to the tapped holes for the sbRIO 9683 or sbRIO 9684 2 Align the sbRIO 9683 or sbRIO 9684 with the M3 29 81 m...

Page 9: ...a Align the handles with the dedicated fixing holes on the sbRIO 9687 b Insert two 8 32 3 8 in panhead screws for each handle through the sbRIO 9687 2 Install the sbRIO 9687 a Install the M3 x 43 36 M...

Page 10: ...ighten M3 x 5 panhead screws through the sbRIO 9687 to the installed M3 x 43 36 M F standoffs and to the M3 x 11 12 M F standoffs e Connect the CAN input cable and the RS232 input cable to sbRIO 9687...

Page 11: ...r sbRIO 9683 or sbRIO 9684 mezzanine board and the sbRIO 9687 GPIC universal interface board Figure 8 Complete Assembly Surface Mounting Dimensions The following figures depict the mounting dimensions...

Page 12: ...Figure 9 Mounting Plate Inches Millimeters 8 0 in 203 2 mm 11 0 in 279 4 mm 16 97 in 430 91 mm 16 47 in 418 21 mm 4X 250 in 6 35 mm 53 in 13 34 mm 12 ni com sbRIO 9687 Getting Started Guide...

Page 13: ...Connecting the sbRIO 9687 The top side of the PCB is the primary side of the sbRIO 9687 and contains connectors for inverter modules simultaneous AI scanned AI and AO feedback inputs digital inputs d...

Page 14: ...nnecting the sbRIO 9607 to the Host Computer Complete the following steps to connect the sbRIO 9607 to the host computer using the RJ 45 Ethernet port 1 Power on the host computer 2 Connect the sbRIO...

Page 15: ...r details about troubleshooting the sbRIO 9607 or the sbRIO 9683 or sbRIO 9684 consult the related documentation If an issue persists after you complete a troubleshooting procedure contact NI technica...

Page 16: ...ns NI 9684 User Manual and Specifications ni com manuals NI sbRIO 9607 9627 RMC Design Guide ni com manuals sbRIO 9687 User Manual ni com manuals sbRIO 9687 Specifications ni com manuals Software Supp...

Page 17: ...the manufacturer s declaration of conformity This system affords the user protection for electromagnetic compatibility EMC and product safety You can obtain the DoC for your product by visiting ni co...

Page 18: ...nts EULAs and third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy an...