Summary of Contents for sbRIO-9637

Page 1: ...n Exercise caution when designing an enclosure for the sbRIO 9637 Auxiliary cooling may be necessary to keep the sbRIO 9637 within the specified operating temperature range Refer to the NI sbRIO 9637 Specifications on ni com manuals for more information about the maximum operating temperature rating For information and examples regarding factors that can affect thermal performance visit ni com inf...

Page 2: ...ries II III or IV Preparing the Environment Ensure that the environment in which you are using the sbRIO 9637 meets the following specifications Local ambient operating temperature near device IEC 60068 2 1 IEC 60068 2 2 40 C to 85 C Maximum reported onboard sensor temperature CPU FPGA temperature 98 C Primary System temperature 85 C Secondary System temperature 85 C Note Ensure that the local amb...

Page 3: ...documentation from the kit Store the device in the antistatic package when the device is not in use Verifying the Kit Contents Verify that the following items are included in the sbRIO 9637 kit Figure 1 sbRIO 9637 Kit Contents 1 2 3 4 5 6 7 8 1 sbRIO Device 2 NI CompactRIO Device Drivers Media 3 Getting Started Guide 4 Power Supply 5 10 pin IDC to 9 pin DSUB Cable 6 50 pin IDC Ribbon Cable 7 Power...

Page 4: ...Info Code softwareversion Connecting the sbRIO 9637 The sbRIO 9637 has the following components Figure 2 sbRIO 9637 Components 1 17 16 20 19 18 15 13 12 2 3 4 5 6 7 8 9 10 11 14 14 1 W3 RS 485 COM3 2 W4 RS 232 COM2 3 J6 SDHC 4 J9 Power Connector 5 Chassis Ground Bracket 6 J10 USB Host Port 7 W1 CAN CAN0 8 J7 RJ 45 Ethernet Port 9 W2 RS 232 COM1 10 Reset Switch 11 LEDs 12 J4 DIO 13 J5 MIO 14 Mounti...

Page 5: ...ntil the connector latches into place 3 Turn on the power supply Powering On the NI sbRIO Device The NI sbRIO device runs a power on self test POST when you apply power to the device During the POST the Power and Status LEDs turn on When the Status LED turns off the POST is complete If the LEDs do not behave in this way when the system powers on refer to the STATUS LED Indicators section Connectin...

Page 6: ...IO 9637 is admin There is no default password for the sbRIO 9637 so you must leave the password field blank when logging in until you set a system password 1 Right click your system and select Web Configuration The NI Web Based Configuration and Monitoring utility opens in your default browser and is where you set the password If you have not installed Microsoft Silverlight NI Web based Configurat...

Page 7: ... is complete Troubleshooting the sbRIO 9637 The sbRIO 9637 is Not Communicating with the Network Ensure that the Ethernet connections between the sbRIO 9637 and the host computer and the Ethernet connections between the host computer and the router are secure Ensure that you have the correct version of NI CompactRIO Device Drivers installed on the host computer Visit ni com info and enter the Info...

Page 8: ...ton for 5 s Run Mode Safe Mode Press and hold RESET button for 5 s Press and hold RESET button for 5 s Press and hold RESET button for 5 s Press and hold RESET button for 5 s Console Out enabled Network settings reset RT Startup App disabled FPGA Startup App disabled Console Out enabled RT Startup App disabled FPGA Startup App disabled Safe Mode STATUS LED Indicators The following table lists the ...

Page 9: ...into safe mode by pressing the reset button for longer than five seconds or by enabling safe mode in MAX Refer to the Measurement Automation Explorer MAX Help for information about safe mode Blinks four times and pauses The sbRIO 9637 is in safe mode The software has crashed twice without rebooting or cycling power between crashes This usually indicates that the sbRIO 9637 has run out of memory Re...

Page 10: ...ments website is your complete resource for technical support At ni com support you have access to everything from troubleshooting and application development self help resources to email and phone assistance from NI Application Engineers Visit ni com services for NI Factory Installation Services repairs extended warranty and other services Visit ni com register to register your National Instrumen...

Page 11: ...nited States visit the Worldwide Offices section of ni com niglobal to access the branch office websites which provide up to date contact information support phone numbers email addresses and current events NI sbRIO 9637 Getting Started Guide National Instruments 11 ...

Page 12: ...nd third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the National Instruments global trade compliance policy and how to obtain relevant HTS codes ECCNs and other import export data NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FO...