background image

Connecting the REM-11154

24 VDC

DI (0:3)

DI (4:7)

DI (8:11)

DI (12:15)

DI (28:31)

DI (24:27)

DI (20:23)

DI (16:19)

Sourcing-Output

Device

GND

x4

REM-11154

+

a1

a2

b1

b2

GND is an optional device-dependent connection.

Verify that the input GND and U

I

 GND have the same potential.

The input signals connect to the DI terminals.

Note

 

For information about fuse ratings for the REM-11154, refer to the device

datasheet on 

ni.com/manuals

.

Connection Guidelines

Make sure that devices you connect to the REM-11154 are compatible with the module
specifications.

Push the wire into the terminal when using a solid wire or a stranded wire with a ferrule.

Open the terminal by pressing a screwdriver into the spring lever when using a stranded
wire without a ferrule.

10

  | 

ni.com

  | 

REM-11154 Getting Started Guide

Summary of Contents for REM-11154

Page 1: ...ght not meet the same safety ratings Refer to the documentation for each component in the system to determine the safety and EMC ratings for the entire system Caution Do not operate the REM 11154 in a...

Page 2: ...nstallations when the product is connected to a peripheral device or test object or if the product is used in residential or commercial areas To minimize interference with radio and television recepti...

Page 3: ...trap or by holding a grounded object such as your computer chassis 1 Touch the antistatic package to a metal part of the computer chassis 2 Remove the device from the package and inspect the device fo...

Page 4: ...ED indicators Table 1 Module Function Labels Label Color Module Function Blue Digital input Red Digital output Green Analog input thermocouple Yellow Analog output White Bus coupler power module Insta...

Page 5: ...bus connector Note A bus connector will not attach to a preceding bus connector with a mounted module Remove the preceding module before installing additional bus connectors 3 Repeat Steps 2 and 3 for...

Page 6: ...directly onto the bus connector and DIN rail until it clicks into place Caution Tilting the module when mounting it on the DIN rail will damage the contacts Installing Spring Terminal Blocks What to U...

Page 7: ...31 DI24 to DI27 DI20 to DI23 DI16 to DI19 00 10 20 30 01 11 21 31 02 12 22 32 03 13 23 33 Table 2 REM 11154 Signal Descriptions Signal Color Description a1 a2 Red 24 VDC UI Supply to digital input mod...

Page 8: ...I23 Digital inputs 20 to 23 60 to 63 DI24 to DI27 Digital inputs 24 to 27 70 to 73 DI28 to DI31 Digital inputs 28 to 31 Figure 3 REM 11154 LEDs D UI 00 02 10 12 11 13 20 22 21 23 30 41 43 51 53 61 63...

Page 9: ...4 has lost connection to the Bus Coupler Flashing The REM 11154 has lost connection to the preceding adjacent module Off The REM 11154 is in reset mode UI Green Solid Supply to digital output module p...

Page 10: ...the DI terminals Note For information about fuse ratings for the REM 11154 refer to the device datasheet on ni com manuals Connection Guidelines Make sure that devices you connect to the REM 11154 ar...

Page 11: ...or from the module Removing the REM 11154 Remove all connections before removing the REM 11154 either by disconnecting the cables or removing the spring terminal block What to Use Flathead Screwdriver...

Page 12: ...us connector 1 3 2 1 Slide the bus connector away from the preceding bus connector at least 5 0 mm 0 20 in 2 Insert the screwdriver and loosen both latches on one side of the DIN rail 3 Rotate the bus...

Page 13: ...t ni com services for NI Factory Installation Services repairs extended warranty and other services Visit ni com register to register your NI product Product registration facilitates technical support...

Page 14: ...Instruments Patent Notice at ni com patents You can find information about end user license agreements EULAs and third party legal notices in the readme file for your NI product Refer to the Export C...

Reviews: