background image

requirements and limits are designed to provide reasonable protection against harmful
interference when the product is operated in its intended operational electromagnetic
environment.

This product is intended for use in residential, commercial, and industrial locations. However,
harmful interference may occur in some installations or when the product is connected to a
peripheral device or a test object. To minimize interference with radio and television reception
and prevent unacceptable performance degradation, install and use this product in strict
accordance with the instructions in the product documentation.

Furthermore, any changes or modifications to the product not expressly approved by National
Instruments could void your authority to operate it under your local regulatory rules.

Caution

 

To ensure the specified EMC performance, operate this product only with

shielded cables and accessories. Do not use unshielded cables or accessories unless
they are installed in a shielded enclosure with properly designed and shielded input/
output ports and connected to the product using a shielded cable. If unshielded
cables or accessories are not properly installed and shielded, the EMC specifications
for the product are no longer guaranteed.

Caution

 

To ensure the specified EMC performance, install two (2) snap-on, ferrite

beads (777297-01) per connected I/O cable in accordance with the product
installation instructions.

Caution

 

To ensure the specified EMC performance, the length of any cable

connected to the input port(s) must be no longer than 3 m (10 ft).

Unpacking the Kit

Caution

 

To prevent electrostatic discharge (ESD) from damaging the device,

ground yourself using a grounding strap or by holding a grounded object, such as
your computer chassis.

1.

Touch the antistatic package to a metal part of the computer chassis.

2.

Remove the device from the package and inspect the device for loose components or any
other sign of damage.

Caution

 

Never touch the exposed pins of connectors.

Note

 

Do not install a device if it appears damaged in any way.

3.

Unpack any other items and documentation from the kit.

Store the device in the antistatic package when the device is not in use.

Verifying the Kit Contents

Verify that the following components are in your kit.

2

  | 

ni.com

  | 

NI PXIe-7822R Getting Started Guide

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Summary of Contents for PXIe-7822R

Page 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Page 2: ...oduct misuse can result in a hazard You can compromise the safety protection built into the product if the product is damaged in any way If the product is damaged return it to National Instruments for...

Page 3: ...lded cable If unshielded cables or accessories are not properly installed and shielded the EMC specifications for the product are no longer guaranteed Caution To ensure the specified EMC performance i...

Page 4: ...ni com manuals for complete specifications Installing Software on the Host Computer Before using the NI PXIe 7822R you must install the following application software and device drivers on the host co...

Page 5: ...nt panel 5 Identify a supported slot in the chassis The following figure shows the symbols that indicate the slot types Figure 2 Chassis Compatibility Symbols NI PXIe 1062Q 1 2 3 4 5 1 PXI Express Sys...

Page 6: ...imize cooling air flow 12 Power on the chassis Verifying Hardware Installation for Host Targets You can verify that the system recognizes the NI PXIe 7822R by using Measurement Automation Explorer MAX...

Page 7: ...t appear press F5 to refresh the view in MAX If the device does not appear after refreshing the view visit ni com support for troubleshooting information Connecting the NI PXIe 7822R NI recommends usi...

Page 8: ...24 59 25 60 26 61 27 62 28 63 29 64 30 65 31 66 32 67 33 68 34 x is the connector number External Clock x is an input only DIO 0 31 Digital I O data through channels 0 through 31 GND Ground reference...

Page 9: ...ers on the DIO channels are set as input low with pull down resistors To set another power on state you can configure the NI PXIe 7822R to load a VI when the system powers on The VI can then set the D...

Page 10: ...ble install two 2 snap on ferrite beads 777297 01 one on each end of the cable as close to the connector as practical Two 2 snap on ferrite beads 777297 01 are included in ach of the following recomme...

Page 11: ...everything from troubleshooting and application development self help resources to email and phone assistance from NI Application Engineers National Instruments corporate headquarters is located at 1...

Page 12: ...le for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the National Instruments global trade compliance policy and how to obtain relevant HTS codes ECC...

Page 13: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Reviews: