10. Close the RFmx SFP and NI-RFSG SFP.
Related Information
Interconnecting the PXIe-5830 Modules
Troubleshooting
If an issue persists after you complete a troubleshooting procedure, search our KnowledgeBase
for additional information our technical support engineers create as they answer common user
questions and resolve unexpected issues.
What Should I Do if the PXIe-3621 Does Not Appear in
MAX?
1.
In the MAX configuration tree, expand
Devices and Interfaces
.
2.
Expand the
Chassis
tree to see the list of installed hardware, and press <F5> to refresh
the list.
3.
If the module is still not listed, power off the system, ensure that all hardware is correctly
installed, and restart the system.
4.
Navigate to the Device Manager.
Operating System
Description
Windows 10/8.1
Right-click the Start button, and select
Device Manager
.
Windows 7
Select
Start
»
Control Panel
»
Device Manager
.
5.
Verify the PXIe-3621 appears in the Device Manager.
a)
Under
NI Modular Instruments
, confirm that a PXIe-3621 entry appears.
Note
If you are using a PC with a device for PXI remote control system,
under
System Devices
, also confirm that no error conditions appear for the
PCI-to-PCI Bridge
.
b)
If error conditions appear, reinstall the driver software and the PXIe-3621.
Why Is the ACCESS LED Off When the Chassis Is
On?
The LEDs may not light until the module has been configured in MAX. Before proceeding,
verify that the module appears in MAX.
If the module appears in MAX but the ACCESS LED fails to light after you power on the
chassis, a problem may exist with the chassis power rails, the hardware module, or the LED.
Notice
Apply external signals only while the hardware is powered on. Applying
external signals while the hardware is powered off may cause damage.
1.
Disconnect any signals from the PXI Express module front panel.