10
|
ni.com
|
NI PXIe-4610 Specifications
Output Switching Noise
Switching noise.................................................10 mV
pk-pk
Switching frequency .........................................0.2 MHz to 2.0 MHz
Output Dynamic Range
Representative FFTs
Measurement conditions for all FFTs:
•
Source: Audio Precision SYS-2722, balanced output, 40
Ω
source impedance.
•
Analyzer: NI PXI-4461, -10 dB gain, differential input.
•
Acquisition: 10 RMS averages of 88,000 samples acquired at 88 kS/s using a 7-term
Blackman-Harris window.
Figure 8.
FFT of -1.0 dBFS, 1 kHz, No Load
Output Dynamic Range* (dBFS)
Typ, 25 °C ±5 °C
Max, 0 °C to 55 °C
114
110
*
1 kHz input tone, -60 dBFS input amplitude.
Evaluation BW = 20 Hz to 20 kHz.
Signal source impedance
≤
50
Ω
.
–160
–140
–120
–100
–80
–60
–40
–20
0
0
10000
20000
30000
40000
M
a
gnit
u
de (dBF
S
)
Freq
u
ency (Hz)