background image

4.

Position the chassis so that inlet and outlet vents are not obstructed.

For more information about optimal chassis positioning, refer to the chassis
documentation.

5.

Remove the black plastic covers from all the captive screws on the module front panel.

6.

Identify a supported slot in the chassis. The following figure shows the symbols that
indicate the slot types.

Figure 2. Chassis Compatibility Symbols

NI PXIe-1062Q

1

2

3

4

5

1. PXI Express System Controller Slot
2. PXI Peripheral Slot
3. PXI Express Hybrid Peripheral Slot

4. PXI Express System Timing Slot
5. PXI Express Peripheral Slot

PXIe-4163 modules can be placed in PXI Express peripheral slots, PXI Express hybrid
peripheral slots, or PXI Express system timing slots.

7.

Touch any metal part of the chassis to discharge static electricity.

8.

Ensure that the ejector handle is in the downward (unlatched) position.

9.

Place the module edges into the module guides at the top and bottom of the chassis. Slide
the module into the slot until it is fully inserted.

Figure 3.  Module Installation

2

3

NI PXIe-1075

1

1. Chassis
2. Hardware Module
3. Ejector Handle in Downward (Unlatched) Position

10. Latch the module in place by pulling up on the ejector handle.

PXIe-4163 Getting Started Guide

  | 

© National Instruments

  | 

5

Summary of Contents for PXIe-4163

Page 1: ...elf Calibrating the PXIe 4163 14 Programming the PXIe 4163 15 Troubleshooting 17 What Should I Do if the PXIe 4163 Doesn t Appear in MAX 17 Why Is the ACCESS LED Off When the Chassis Is On 18 What Sho...

Page 2: ...urself using a grounding strap or by holding a grounded object such as your computer chassis 1 Touch the antistatic package to a metal part of the computer chassis 2 Remove the module from the package...

Page 3: ...number 142947B 02 SHDB62M BW LL Low Leakage Cable for SMU 62 D Sub Male to Bare Wire Male 1 m NI part number 142948A 01 2 m NI part number 142948A 02 62 Pin Connector Kit for PXIe 416x SMUs NI part n...

Page 4: ...ompts Note Windows users may see access and security messages during installation Accept the prompts to complete the installation 5 When the installer completes select Restart in the dialog box that p...

Page 5: ...PXI Express System Timing Slot 5 PXI Express Peripheral Slot PXIe 4163 modules can be placed in PXI Express peripheral slots PXI Express hybrid peripheral slots or PXI Express system timing slots 7 To...

Page 6: ...slots using EMC filler panels or fill using slot blockers to maximize cooling air flow depending on your application 13 Power on the chassis Related Information Why Is the ACCESS LED Off When the Chas...

Page 7: ...ltage generation sources through output disconnect relays Green At least one device output is connected to a voltage generation source Red The device has a fault or is in error due to the voltage gene...

Page 8: ...2 Sense HI CH17 Output HI CH17 Sense HI CH18 Output HI CH18 Sense HI CH23 Output HI CH23 Sense HI CH1 Output HI CH1 Sense HI CH0 5 Sense LO CH4 Output HI CH4 Sense HI CH7 Output HI CH7 Sense HI CH6 11...

Page 9: ...Signal Description A 0 61 Sense HI 62 Output HI 1 41 Sense HI 42 Output HI 2 19 Sense HI 20 Output HI 3 17 Sense HI 18 Output HI 4 38 Sense HI 39 Output HI 5 59 Sense HI 60 Output HI 0 to 5 40 Sense L...

Page 10: ...annel Pin Signal Description B 6 56 Sense HI 57 Output HI 7 36 Sense HI 37 Output HI 8 14 Sense HI 15 Output HI 9 12 Sense HI 13 Output HI 10 33 Sense HI 34 Output HI 11 54 Sense HI 55 Output HI 6 to...

Page 11: ...in Signal Description C 12 50 Sense HI 51 Output HI 13 30 Sense HI 31 Output HI 14 8 Sense HI 9 Output HI 15 6 Sense HI 7 Output HI 16 27 Sense HI 28 Output HI 17 48 Sense HI 49 Output HI 12 to 17 29...

Page 12: ...ense HI 46 Output HI 19 25 Sense HI 26 Output HI 20 3 Sense HI 4 Output HI 21 1 Sense HI 2 Output HI 22 22 Sense HI 23 Output HI 23 43 Sense HI 44 Output HI 18 to 23 24 Sense LO A B C D 0 to 23 10 Out...

Page 13: ...Grouping Output HI 37 36 35 36 35 34 33 Output HI Sense HI Channel 6 Grouping Sense HI Channel 7 Grouping Output HI Output HI A B C D Bundle Channels A 0 to 5 B 6 to 11 C 12 to 17 D 18 to 23 Configur...

Page 14: ...complete self calibration after the first time you install the PXIe 4163 1 Install the PXIe 4163 and let it warm up for 30 minutes Note Warm up begins when the PXI Express chassis has been powered on...

Page 15: ...You can generate signals interactively using InstrumentStudio or you can use the NI DCPower instrument driver to program your device in the supported ADE of your choice PXIe 4163 Getting Started Guid...

Page 16: ...devices From the Windows start menu select National Instruments InstrumentStudio 2018 This launches InstrumentStudio and runs a soft front panel populated with devices detected on your system From Me...

Page 17: ...ndation IVI Refer to the Creating an Application with NI DCPower in Microsoft Visual C and C topic of the NI DC Power Supplies and SMUs Help to manually add all required include and library files to y...

Page 18: ...on Applying external signals while the module is powered off may cause damage 1 Disconnect any signals from the module front panels 2 Power off the chassis 3 Remove the module from the chassis and ins...

Page 19: ...support Services ni com services PXIe 4163 Specifications NI Community ni com community Power Supplies Solutions ni com powersupplies Worldwide Support and Services The NI website is your complete re...

Page 20: ...nt Notice at ni com patents You can find information about end user license agreements EULAs and third party legal notices in the readme file for your NI product Refer to the Export Compliance Informa...

Reviews: