Figure 2. PXIe-4162 Pinout

CH1 Output HI

CH1 Sense HI

CH10 Sense LO

Calibration HI

CH10 Sense HI

CH10 Guard

CH10 Output HI

CH7 Guard

CH7 Sense LO

CH7 Output HI

CH7 Sense HI

CH0 to 11 Output LO

CH4 Guard

CH4 Sense LO

CH4 Output HI

CH4 Sense HI

CH1 Sense LO

CH1 Guard

CH0 Output HI

CH0 Sense HI

CH2 Guard

CH2 Sense LO

CH3 Output HI

CH3 Sense HI

CH5 Guard

CH5 Sense LO

CH6 Output HI

CH6 Sense HI

CH8 Guard

CH8 Sense LO

CH9 Output HI

CH9 Sense HI

CH11 Guard

CH11 Sense LO

CH0 Guard

CH0 Sense LO

NC

CH2 Output HI

CH2 Sense HI

CH3 Guard

CH3 Sense LO

NC

CH5 Output HI

CH5 Sense HI

CH6 Guard

CH6 Sense LO

NC

CH8 Output HI

CH8 Sense HI

CH9 Guard

CH9 Sense LO

NC

CH11 Output HI

CH11 Sense HI

62

61

60

59

56

55

54

57

50

49

48

51

45

44

43

46

20

21

19

18

17

14

13

12

15

8

7

6

9

10

3

2

1

4

42

41

40

39

38

37

36

35

34

33

31

30

29

28

27

26

25

24

23

22

4

  | 

ni.com

  | 

PXIe-416x Noise Filter Accessory User Guide

Summary of Contents for PXIe-416 Series

Page 1: ...modify the behavior of the PXIe 4162 PXIe 4163 SMU when the module is used in remote sense mode Caution Observe all instructions and cautions in the user documentation Using the product in a manner n...

Page 2: ...formation about the PXIe 4162 PXIe 4163 Installing the PXIe 416x Noise Filter Accessory Complete the following steps to install the PXIe 416x Noise Filter Accessory with a PXIe 416x Before you begin i...

Page 3: ...ry to the PXIe 416x Noise Filter Accessory Refer to your cable or accessory documentation for more information Refer to the following pinouts for your respective module to make the appropriate connect...

Page 4: ...5 Guard CH5 Sense LO CH6 Output HI CH6 Sense HI CH8 Guard CH8 Sense LO CH9 Output HI CH9 Sense HI CH11 Guard CH11 Sense LO CH0 Guard CH0 Sense LO NC CH2 Output HI CH2 Sense HI CH3 Guard CH3 Sense LO N...

Page 5: ...ense HI CH19 Output HI CH19 Sense HI CH18 23 Sense LO CH22 Output HI CH22 Sense HI 62 61 60 59 56 55 54 57 50 49 48 51 45 44 43 46 20 21 19 18 17 14 13 12 15 8 7 6 9 10 3 2 1 4 42 41 40 39 38 37 36 35...

Page 6: ...l unless otherwise noted Derating Remote Sense Maximum sense lead resistance 100 Maximum force lead drop 1 V Voltage accuracy Add 200 V to the accuracy specification for your respective module when us...

Page 7: ...he Environment web page at ni com environment This page contains the environmental regulations and directives with which NI complies as well as other environmental information not included in this doc...

Page 8: ...compliance for more information and to request relevant import classification codes e g HTS export classification codes e g ECCN and other import export data Product Certifications and Declarations Re...

Page 9: ...n about NI service offerings such as calibration options repair and replacement Visit ni com register to register your NI product Product registration facilitates technical support and ensures that yo...

Page 10: ...EULAs and third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and h...

Reviews: