National Instruments PXI-8231 Installation Manual Download Page 5

©

 National Instruments Corporation

5

NI PXI-8231 Installation Guide

Link LED Is Not Lit When Computer Is Shut Down and Power Is 
Connected

Make sure the network cable is attached.

PXI Installation Tips

PXI computers are designed to configure add-in boards automatically each 
time the computer starts. The PXI computer sets the I/O address and IRQ 
level for the peripheral boards when the computer starts. The network 
drivers cannot change these values. If you experience problems when the 
computer starts, you may need to follow additional steps.

On some computers, manual configuration is possible through the 
computer’s BIOS setup utility. Refer to the documentation for your 
computer. You may need to verify or change some BIOS settings.

The following common solutions may correct your problem:

Make sure you have installed the adapter in a bus master-enabled slot. 
On some computers, not all slots are bus master enabled by default. 
Check your BIOS settings. Enable PXI bus mastering, if your BIOS 
has such an option.

Reserve interrupts (IRQ) and/or memory addresses for ISA adapters. 
This prevents PXI boards from using the same settings ISA boards are 
using. Try changing some of the interrupts reserved for ISA, but not 
being used, to reserved for PXI.

Update your BIOS. Sometimes updating the BIOS corrects some 
configuration problems.

Configure the PXI slot for level-triggered interrupts instead of 
edge-triggered interrupts in BIOS.

Ethernet Adapter Specifications

LEDs

Green............................................... Activity/Link

Yellow/Green.................................. Speed

Refer to 

ni.com/products

 for complete specifications.