The NI PXI-8214 is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced 
by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to be defective during the 
warranty period. This warranty includes parts and labor. 

The media on which you receive National Instruments software are warranted not to fail to execute programming instructions, due to defects 
in materials and workmanship, for a period of 90 days from date of shipment, as evidenced by receipts or other documentation. National 
Instruments will, at its option, repair or replace software media that do not execute programming instructions if National Instruments receives 
notice of such defects during the warranty period. National Instruments does not warrant that the operation of the software shall be 
uninterrupted or error free.

A Return Material Authorization (RMA) number must be obtained from the factory and clearly marked on the outside of the package before 
any equipment will be accepted for warranty work. National Instruments will pay the shipping costs of returning to the owner parts which are 
covered by warranty.

National Instruments believes that the information in this document is accurate. The document has been carefully reviewed for technical 
accuracy. In the event that technical or typographical errors exist, National Instruments reserves the right to make changes to subsequent 
editions of this document without prior notice to holders of this edition. The reader should consult National Instruments if errors are suspected. 
In no event shall National Instruments be liable for any damages arising out of or related to this document or the information contained in it.

E

XCEPT

 

AS

 

SPECIFIED

 

HEREIN

, N

ATIONAL

 I

NSTRUMENTS

 

MAKES

 

NO

 

WARRANTIES

EXPRESS

 

OR

 

IMPLIED

AND

 

SPECIFICALLY

 

DISCLAIMS

 

ANY

 

WARRANTY

 

OF

 

MERCHANTABILITY

 

OR

 

FITNESS

 

FOR

 

A

 

PARTICULAR

 

PURPOSE

. C

USTOMER

S

 

RIGHT

 

TO

 

RECOVER

 

DAMAGES

 

CAUSED

 

BY

 

FAULT

 

OR

 

NEGLIGENCE

 

ON

 

THE

 

PART

 

OF

 

N

ATIONAL

 I

NSTRUMENTS

 

SHALL

 

BE

 

LIMITED

 

TO

 

THE

 

AMOUNT

 

THERETOFORE

 

PAID

 

BY

 

THE

 

CUSTOMER

. N

ATIONAL

 I

NSTRUMENTS

 

WILL

 

NOT

 

BE

 

LIABLE

 

FOR

 

DAMAGES

 

RESULTING

 

FROM

 

LOSS

 

OF

 

DATA

PROFITS

USE

 

OF

 

PRODUCTS

OR

 

INCIDENTAL

 

OR

 

CONSEQUENTIAL

 

DAMAGES

EVEN

 

IF

 

ADVISED

 

OF

 

THE

 

POSSIBILITY

 

THEREOF

. This limitation of the liability of National Instruments will apply regardless of the form of action, whether in contract or tort, including 

negligence. Any action against National Instruments must be brought within one year after the cause of action accrues. National Instruments 
shall not be liable for any delay in performance due to causes beyond its reasonable control. The warranty provided herein does not cover 
damages, defects, malfunctions, or service failures caused by owner’s failure to follow the National Instruments installation, operation, or 
maintenance instructions; owner’s modification of the product; owner’s abuse, misuse, or negligent acts; and power failure or surges, fire, 
flood, accident, actions of third parties, or other events outside reasonable control.

Copyright

Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying, 
recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National 
Instruments Corporation.

Trademarks

National Instruments

, NI

, and ni.com

 are trademarks of National Instruments Corporation.

Product and company names mentioned herein are trademarks or trade names of their respective companies.

Patents

For patents covering National Instruments products, refer to the appropriate location: 

Help»Patents

 in your software, the 

patents.txt

 file 

on your CD, or 

ni.com/patents

.

WARNING REGARDING USE OF NATIONAL INSTRUMENTS PRODUCTS

(1) NATIONAL INSTRUMENTS PRODUCTS ARE NOT DESIGNED WITH COMPONENTS AND TESTING FOR A LEVEL OF 
RELIABILITY SUITABLE FOR USE IN OR IN CONNECTION WITH SURGICAL IMPLANTS OR AS CRITICAL COMPONENTS IN 
ANY LIFE SUPPORT SYSTEMS WHOSE FAILURE TO PERFORM CAN REASONABLY BE EXPECTED TO CAUSE SIGNIFICANT 
INJURY TO A HUMAN.

(2) IN ANY APPLICATION, INCLUDING THE ABOVE, RELIABILITY OF OPERATION OF THE SOFTWARE PRODUCTS CAN BE 
IMPAIRED BY ADVERSE FACTORS, INCLUDING BUT NOT LIMITED TO FLUCTUATIONS IN ELECTRICAL POWER SUPPLY, 
COMPUTER HARDWARE MALFUNCTIONS, COMPUTER OPERATING SYSTEM SOFTWARE FITNESS, FITNESS OF COMPILERS 
AND DEVELOPMENT SOFTWARE USED TO DEVELOP AN APPLICATION, INSTALLATION ERRORS, SOFTWARE AND 
HARDWARE COMPATIBILITY PROBLEMS, MALFUNCTIONS OR FAILURES OF ELECTRONIC MONITORING OR CONTROL 
DEVICES, TRANSIENT FAILURES OF ELECTRONIC SYSTEMS (HARDWARE AND/OR SOFTWARE), UNANTICIPATED USES OR 
MISUSES, OR ERRORS ON THE PART OF THE USER OR APPLICATIONS DESIGNER (ADVERSE FACTORS SUCH AS THESE ARE 
HEREAFTER COLLECTIVELY TERMED “SYSTEM FAILURES”). ANY APPLICATION WHERE A SYSTEM FAILURE WOULD 
CREATE A RISK OF HARM TO PROPERTY OR PERSONS (INCLUDING THE RISK OF BODILY INJURY AND DEATH) SHOULD 
NOT BE RELIANT SOLELY UPON ONE FORM OF ELECTRONIC SYSTEM DUE TO THE RISK OF SYSTEM FAILURE. TO AVOID 
DAMAGE, INJURY, OR DEATH, THE USER OR APPLICATION DESIGNER MUST TAKE REASONABLY PRUDENT STEPS TO 
PROTECT AGAINST SYSTEM FAILURES, INCLUDING BUT NOT LIMITED TO BACK-UP OR SHUT DOWN MECHANISMS. 
BECAUSE EACH END-USER SYSTEM IS CUSTOMIZED AND DIFFERS FROM NATIONAL INSTRUMENTS' TESTING 
PLATFORMS AND BECAUSE A USER OR APPLICATION DESIGNER MAY USE NATIONAL INSTRUMENTS PRODUCTS IN 
COMBINATION WITH OTHER PRODUCTS IN A MANNER NOT EVALUATED OR CONTEMPLATED BY NATIONAL 
INSTRUMENTS, THE USER OR APPLICATION DESIGNER IS ULTIMATELY RESPONSIBLE FOR VERIFYING AND VALIDATING 
THE SUITABILITY OF NATIONAL INSTRUMENTS PRODUCTS WHENEVER NATIONAL INSTRUMENTS PRODUCTS ARE 
INCORPORATED IN A SYSTEM OR APPLICATION, INCLUDING, WITHOUT LIMITATION, THE APPROPRIATE DESIGN, 
PROCESS AND SAFETY LEVEL OF SUCH SYSTEM OR APPLICATION.

Summary of Contents for PXI-8214

Page 1: ...PXI NI PXI 8214 User Manual NI PXI 8214 User Manual October 2002 Edition Part Number 323455A 01...

Page 2: ...8 14 24 24 Germany 089 741 31 30 Greece 01 42 96 427 Hong Kong 2645 3186 India 91 80 4190000 Israel 03 6393737 Italy 02 413091 Japan 03 5472 2970 Korea 02 3451 3400 Malaysia 603 9596711 Mexico 001 800...

Page 3: ...ents installation operation or maintenance instructions owner s modification of the product owner s abuse misuse or negligent acts and power failure or surges fire flood accident actions of third part...

Page 4: ...ruments could void the user s authority to operate the equipment under the FCC Rules Class A Federal Communications Commission This equipment has been tested and found to comply with the limits for a...

Page 5: ...ncludes a DoC for most every hardware product except for those bought for OEMs if also available from an original manufacturer that also markets in the EU or where compliance is not required as for el...

Page 6: ...text denotes items that you must select or click in the software such as menu items and dialog box options Bold text also denotes parameter names italic Italic text denotes variables emphasis a cross...

Page 7: ...2 Connectors 1 2 Chapter 2 Installation What You Need to Get Started 2 1 Installing the PXI 8214 2 1 Driver Installation 2 3 Windows XP 2 3 Windows 2000 2 3 Windows NT 2 3 Windows 98 2 4 Linux 2 4 Dev...

Page 8: ...ed continuous disk operation PXI 8214 Features The PXI 8214 includes the following features LSI53C895A PXI to Ultra2 SCSI controller PXI cPCI interface Supports 32 bit DMA bus master with 64 bit addre...

Page 9: ...5 SCSI devices including CD ROM drives hard disks printers and scanners This interface can support single ended and low voltage differential LVD devices Connectors There are two connectors Connector P...

Page 10: ...n Electrostatic discharge can damage several components on the PXI 8214 To avoid such damage in handling the board touch the antistatic plastic package to a metal part of your system chassis before re...

Page 11: ...e catches on the injector ejector rail 6 Raise the injector ejector handle until the module firmly seats into the backplane receptacle connectors The front panel of the PXI 8214 should be even with th...

Page 12: ...ver diskette into your floppy disk drive 3 Windows 2000 should find the proper driver You can verify installation in the Device Manager After verifying that your operating system recognizes the PXI 82...

Page 13: ...Device Manager After verifying that your operating system recognizes the PXI 8214 properly power down your system and connect your devices according to the Device Connection Guide section Linux Instru...

Page 14: ...ation for the other bus end You can use 8 bit devices such as most SCSI CD ROMs but you must be careful when cabling and terminating these devices If only 8 bit devices reside on the SCSI bus you can...

Page 15: ...SI bus In most applications you should use the default configuration To disable termination on the PXI 8214 you must set both the SW1 1 and SW1 2 switches to the OFF position In all setups both switch...

Page 16: ...ons 10 0 by 16 0 cm 3 9 by 6 3 in Slot requirements One peripheral slot Weight 0 13 kg 0 28 lb Temperature 0 to 50 C operating 20 to 70 C storage Relative humidity 10 to 90 noncondensing operating 5 t...

Page 17: ...iant Electromagnetic emissions EN 55011 Class A at 10 meters FCC Part 15A above 1 GHz Electromagnetic immunity Evaluated to EN 61326 1997 A1 1998 Table 1 Note For EMC compliance operate this device wi...

Page 18: ...Assisted Support Options Contact NI engineers and other measurement and automation professionals by visiting ni com ask Our online system helps you define your question and connects you to the experts...