NI PXI-8195/8196 Installation Guide
Figure 2 shows an NI PXI-8195/8196 controller installed in the system
controller slot of a National Instruments PXI-1042 chassis. You can place
PXI devices in any other slot.
Figure 2.
NI 8195/8196 Installed in a PXI Chassis
How to Remove the Controller from the PXI Chassis
The NI PXI-8195/8196 controllers are designed for easy handling. To
remove the unit from the PXI chassis:
1.
Turn off power.
2.
Remove the bracket-retaining screws in the front panel.
3.
Press the injector/ejector handle down.
4.
Slide the unit out of the chassis.
What If the NI PXI-8195/8196 Does Not Boot?
Several problems can cause a controller not to boot. Here are some things
to look for and possible solutions.
Things to Notice
•
Which LEDs come on? The
Power OK
LED should stay lit. The
Drive
LED should blink during boot as the disk is accessed.
•
What appears on the display? Does it hang at some particular point
(BIOS, Operating System, etc.)? If nothing appears on the screen, try
a different monitor. Does your monitor work with a different PC? If it
hangs, note the last screen output that you saw for reference when
consulting National Instruments technical support.