DC path resistance typically remains low for the life of the relay. At the end of relay life, the
path resistance rises rapidly above 1 Ω. Load ratings apply to relays used within the
specification before the end of relay life.
Thermal EMF
≤12 μV, typical
Bandwidth (-3 dB, 50 Ω termination)
≥40 MHz, typical
Crosstalk (50 Ω termination, channel-to-channel)
10 kHz
≤-85 dB, typical
100 kHz
≤-70 dB, typical
1 MHz
≤-50 dB, typical
10 MHz
≤-30 dB, typical
Isolation (50 Ω termination, open channel)
10 kHz
≥85 dB, typical
100 kHz
≥65 dB, typical
1 MHz
≥45 dB, typical
10 MHz
≥25 dB, typical
Dynamic Characteristics
Maximum cycle speed
145 cycles/s
Relay operate time
1 ms, typical
3.4 ms maximum
Note
Certain applications may require additional time for proper settling. Refer to
the
NI Switches Help
for more information about including
additional settling time.
Expected relay life
Mechanical
1 × 10
8
cycles
Electrical
10 VDC, 100 mADC resistive
2.5 × 10
6
cycles
10 VDC, 1 ADC resistive
1 × 10
6
cycles
30 VDC, 1 ADC resistive
5 × 10
5
cycles
30 VDC, 2 ADC resistive
1 × 10
5
cycles
Note
Relays are field replaceable. Refer to the
NI Switches Help
at
for more information about replacing a failed relay.
NI PXI-2568 Specifications
|
© National Instruments
|
3