background image

PXI-1000B AC Power Supply Shuttle Installation Guide

4

ni.com

Getting Started

This section describes the key features of the PXI-1000B AC power supply
shuttle and lists the contents of your kit.

Unpacking

Carefully inspect the shipping container and the power supply shuttle for
damage. Check for visible damage to the metal work. Check to make sure
all handles, hardware, and switches are undamaged. Inspect the power
supply shuttle for any possible debris or detached components. If shipment
appears to have caused damage, file a claim with the carrier. Retain the
packing material for possible inspection and/or reshipment.

What You Need to Get Started

The PXI-1000B AC power supply shuttle kit contains the following items:

PXI-1000B AC power supply shuttle assembly

This installation guide

You must provide an AC power cable. See Table 1 for a list of cables.

Key Features

The PXI-1000B AC power supply shuttle combines a high-performance,
high-output power supply and a structural design optimized for maximum
usability in a wide range of applications. The power supply shuttle fully
complies with the PXI Specification, Revision 1.0.

The key features of the PXI-1000B AC power supply shuttle include:

300 W of usable power

Universal AC input: auto-voltage and auto-frequency ranging

Over-current protection via push-reset circuit breaker (no loose fuses
to replace)

Remote power status and inhibit via a rear panel connector

Selectable fan speed for maximum cooling or quiet operation

Table 1.

AC Power Cables

Power Cable

Reference Standards

Standard 120 V (USA)

ANSI C73.11/NEMA 5-15-P/IEC83

Switzerland 220 V

SEV

Australia 240 V

AS C112

Summary of Contents for PXI 1000B

Page 1: ...GUIDE PXI 1000B AC POWER SUPPLY SHUTTLE Contents Important Information 2 For Your Safety 3 Getting Started 4 Unpacking 4 What You Need to Get Started 4 Key Features 4 Removal Configuration and Instal...

Page 2: ...wner s modification of the product owner s abuse misuse or negligent acts and power failure or surges fire flood accident actions of third parties or other events outside reasonable control Copyright...

Page 3: ...he PXI 1000B AC power supply shuttle Adjustments and service to internal components must be undertaken by qualified service technicians During service of this product the mains connector to the premis...

Page 4: ...items PXI 1000B AC power supply shuttle assembly This installation guide You must provide an AC power cable See Table 1 for a list of cables Key Features The PXI 1000B AC power supply shuttle combines...

Page 5: ...power supply shuttle Figure 2 shows a rear view Figure 1 Isometric View of the PXI 1000B AC Power Supply Shuttle Figure 2 Rear View of the PXI 1000B AC Power Supply Shuttle 1 Module Cooling Air Outle...

Page 6: ...rd from the power supply shuttle on the back of the chassis Identify the six captive screws that attach the power supply shuttle to the chassis Using a Phillips screwdriver loosen the captive screws P...

Page 7: ...rs or a toothed lug Connecting to Power Source and Testing Power Up Caution Remove all PXI modules from the PXI 1000B chassis prior to performing the first power on test 1 Attach the appropriate power...

Page 8: ...PXI 1000B AC power supply shuttle supports remote power monitoring and inhibiting via a 9 pin D sub connector on the rear panel Table 3 shows the pinout of the DB 9 connector Table 2 Power Supply Volt...

Page 9: ...ths Depending on the amount of use and ambient dust levels in the operating environment the filters may require more frequent cleaning Clean dust from the exterior and interior as needed based on the...

Page 10: ...st enough moisture to dampen the cloth Do not wash the rear panel connectors or switches Cover these components while cleaning the power supply shuttle Do not use chemical cleaning agents they may dam...

Page 11: ......

Page 12: ......

Reviews: