Table 2.  

I/O Connector Signals

Signal Name

Function

IN0

Opto-coupled auxiliary input signal 0.

*

IN1

Opto-coupled auxiliary input signal 1.

*

IN2

Opto-coupled auxiliary input signal 2.

*

IN3

Opto-coupled auxiliary input signal 3.

*

TRIGIN

Opto-isolated trigger input signal.

24 V IN

Supplies power to the accessory and smart camera.

OUT0

Open collector ouput signal 0.

Provides an exposure signal generated using exposure timer 1 or trigger signal bypass.

OUT1

Open collector output signal 1.

Provides an exposure signal, trigger signal bypass, or programmable unmodulated 
strobe signal generated using exposure timer 2.

OUT2

Open collector output signal 2.

OUT3

Open collector output signal 3.

LED DRV

Controlled-current output, designed to be connected to a LED lighting device (0 to 
500 mA, generated using exposure timer 2).

24 V OUT

Power supply output.

SAFE MODE

Initializes the camera in safe mode.

The negative component of this signal is internally connected to the power supply GND.