![background image](http://html1.mh-extra.com/html/national-instruments/pcie-1433/pcie-1433_user-manual-and-specifications_3390019027.webp)
Appendix A
Specifications
©
National Instruments Corporation
A-3
NI PCIe-1433 User Manual and Specifications
Environment
The NI 1433 is intended for indoor use only.
Operating Environment
Operating temperature............................ 0 °C to 50 °C
Tested in accordance
with IEC-60068-2-1
and IEC-60068-2-2.
Relative humidity range ......................... 10% to 90%, noncondensing
Tested in accordance with
IEC-60068-2-56.
Altitude................................................... 2,000 m at 25 °C ambient
temperature
Pollution Degree .................................... 2
Storage Environment
Ambient temperature range.................... –20 °C to 70 °C
Tested in accordance
with IEC-60068-2-1
and IEC-60068-2-2.
Relative humidity range ......................... 5% to 95%, noncondensing
Tested in accordance with
IEC-60068-2-56.
Note
Clean the device with a soft, non-metallic brush. Make sure the device is completely
dry and free from contaminants before returning it to service.
Shock and Vibration
Operational shock .................................. 30 g peak, half-sine, 11 ms pulse
Tested in accordance with
IEC-60068-2-27. Test profile
developed in accordance with
MIL-PRF-28800F.