Chapter 3
Signal Connections
©
National Instruments Corporation
3-13
PC-DIO-24/PnP User Manual
Mode 1 Output Timing
The following figure illustrates the timing specifications for an output
transfer in mode 1.
Figure 3-6.
Mode 1 Timing Specification for Output Transfers
Name
Description
Minimum
Maximum
T1
WR* = 0 to INTR = 0
—
250
T2
WR* = 1 to output
—
200
T3
WR* = 1 to OBF* = 0
—
150
T4
ACK* = 0 to OBF* = 1
—
150
T5
ACK* pulse width
100
—
T6
ACK* = 1 to INTR = 1
—
150
All timing values are in nanoseconds.
T2
T3
WR*
OBF*
INTR
DATA
T4
T6
T5
ACK*
T1