Connect the Hardware 

Caution

Before installing NI CVS-1450 Series hardware, refer to the safety 

information in the 

NI CVS-1450 Series User Manual

.

Connect the Camera and Monitor to the NI CVS-1450 Device

A.

Connect the VGA Cable
from the monitor to 
the VGA port on the 
NI CVS-1450 device.

B.

Plug the IEEE 1394
cable into one of the
IEEE 1394 ports on the 
NI CVS-1450 device. 
Plug the other end of
the cable into the IEEE
1394 port of the camera.

C.

Plug in and power on
the monitor.

Wire Power to the NI CVS-1450 Device

This section explains how to connect the power supply (part number 778794-01) 
to the NI CVS-1450 device. For instructions on how to connect a separate main supply, 
refer to the 

NI CVS-1450 Series User Manual

Caution

Do 

not

connect the NI CVS-1450 device to a power source other than 

24 VDC +10%. Refer to the 

NI CVS-1450 Series User Manual

for information about 

power requirements.

D.

Plug the 4-position connector from the power supply into the power receptacle 
on the NI CVS-1450 device.

E.

Plug the power cord into the power supply.

F.

Plug the power cord into an outlet.

Once connected, the NI CVS-1450 device runs a startup program that acquires images and
displays them on the monitor. These images verify that the hardware is properly connected.

Connect the NI CVS-1450 Device to the Development Computer

Verify that the development computer is connected to the network and powered on.

G.

Using a standard CAT 5 Ethernet cable (part number 189174), connect from the 
network port to the Ethernet port on the NI CVS-1450 device.

H.

Using a standard CAT 5 Ethernet cable, connect from the network port to the 
Ethernet port on the development computer.

Note

If you are not connecting through a network, use a crossover cable 

(part number 187375) to connect the NI CVS-1450 device to the development 
computer.

G

H

F

To Outlet

E

D

1

QUICK START GUIDE

NI CVS-1450 Series Compact Vision System

LabVIEW Real-Time Module with the 
NI Vision Development Module

A

C

B

Install the Software

Note

You must install LabVIEW, the LabVIEW Real-Time Module, and the NI Vision

Development Module software 

before

installing the NI-IMAQ for IEEE 1394 Cameras

driver software. 

Install LabVIEW and the LabVIEW Real-Time Module

A.

Insert the LabVIEW CD. When the installation screen appears, click 

Install LabVIEW

and

follow the setup instructions.

B.

Insert the LabVIEW Real-Time Module CD. When the installation screen appears, 
click 

Install LabVIEW Real-Time Module

and follow the setup instructions.

Install the NI Vision Development Module and NI-IMAQ for IEEE 1394 Cameras

C.

Insert the NI Vision Development Module CD. When the installation screen appears, 
click 

Install NI Vision Development Module

and follow the setup instructions.

D.

When prompted, insert the NI Vision Acquisition Software CD.

E.

In the 

Features

tree, select 

NI-IMAQ for IEEE 1394 Cameras

and 

NI-IMAQ for IEEE 1394

Hardware Support

F.

Click 

Next

.

G.

Follow the installer prompts to complete the installation.

2

Configure the NI CVS-1450 Device

Obtain an IP Address

A.

Launch Measurement & Automation Explorer (MAX) and expand the 

Remote Systems

branch of the configuration tree.

B.

Click 

192.168.10.12

to display the Network Settings window. This IP address is assigned to 

all unconfigured NI CVS-1450 devices.

Tip

To uniquely identify unconfigured NI CVS-1450 devices, connect and configure 

one NI CVS-1450 device at a time.

C.

In the Network Settings window, type a name for the NI CVS-1450 device in the N

Na

am

me

e field 

and a description of the NI CVS-1450 device in the C

Co

om

mm

me

en

ntt field

Note

Device names are limited to 15 characters with no spaces or special characters. 

The first and last letters must be alphanumeric devices.

D.

If the network is configured to issue IP addresses using DHCP, select 

Obtain IP address 

from DHCP server

. Otherwise, set the IP address manually by selecting 

Edit the IP settings

Suggest Values

, and 

OK

.

E.

Click 

Apply

. When prompted, click 

Yes

to restart the NI CVS-1450 device. This initial 

installation process takes several minutes.

While the NI CVS-1450 device is restarting, a red X          appears next to the 
device name to indicate that the NI CVS-1450 device is disconnected.

The MAX status bar also indicates the connection status of the NI CVS-1450 device.

Download Software to the NI CVS-1450 Device

F.

In the MAX configuration tree, expand the device folder by clicking the plus sign next to 
the device name.

G.

Click the S

So

offttw

wa

arre

e branch.

H.

Click the A

Ad

dd

d//R

Re

em

mo

ovve

e  S

So

offttw

wa

arre

e button.

I.

Select the software to install on the NI CVS-1450 device.

J.

Click 

Next

.

The NI CVS-1450 device will automatically restart. This process takes several seconds.

3

Acquire an Image

You can acquire an image using MAX or the LabVIEW Real-Time Module.

Acquire an Image using MAX

A.

Launch MAX.

B.

In the MAX configuration tree, 
expand the device folder.

C.

Expand D

De

evviic

ce

ess  a

an

nd

d  IIn

ntte

errffa

ac

ce

ess.

D.

Expand N

NII--IIM

MA

AQ

Q  IIE

EE

EE

E  11339944  D

De

evviic

ce

ess.

E.

Select a camera.

F.

Click the S

Sn

na

ap

p button to acquire 

a single image, or click the G

Grra

ab

b

button to acquire continuous 
images.

Acquire an Image using the LabVIEW Real-Time Module

A.

Launch LabVIEW, and select to 
create a new 

Real-Time Project

.

B.

Select 

Custom project

for the 

Project type

, enter a 

Project name

,

select the 

Project folder

where you

want to store the project, and click

Next

.

C.

Select 

Add blank vi to target

and click 

Next

.

D.

Select the 

Networked

option for

Browse targets, and click 

Browse

.

E.

Select the 

Existing target or device

option from Targets and Devices,
expand the 

Compact Vision System

branch, select your device, and 
click 

OK

.

F.

Click 

Next

.

G.

Verify that the NI CVS-1450 device
appears correctly in the LabVIEW
Real-Time Project, and click FFiin

niissh

h.

H.

In the Project Explorer window, 
right-click the name of your 
NI CVS-1450 device, and select 

Add File

.

I.

Navigate to 

Program Files\

National Instruments\

LabVIEW 8.0\examples\

IMAQ\IMAQ1394

examples.llb

, and click 

Add File

.

J.

Click 

Grab.vi

, and click 

Select

.

K.

Click the 

Run

button to begin acquiring images.

Now that you are acquiring images in LabVIEW, you can use the NI Vision Development Module
and the installed NI CVS-1450 device drivers to process images and to control inputs and outputs.

4

Summary of Contents for NI Vision CVS-1450 Series

Page 1: ...n about power requirements D Plug the 4 position connector from the power supply into the power receptacle on the NI CVS 1450 device E Plug the power cord into the power supply F Plug the power cord into an outlet Once connected the NI CVS 1450 device runs a startup program that acquires images and displays them on the monitor These images verify that the hardware is properly connected Connect the...

Page 2: ...een appears click Install Vision Builder for Automated Inspection and follow the setup instructions Install NI IMAQ for IEEE 1394 Cameras B When prompted insert the NI Vision Acquisition Software CD C In the Features tree select N NI I I IM MA AQ Q f fo or r I IE EE EE E 1 13 39 94 4 C Ca am me er ra as s and N NI I I IM MA AQ Q f fo or r I IE EE EE E 1 13 39 94 4 H Ha ar rd dw wa ar re e S Su up ...

Page 3: ...me for the NI CVS 1450 device in the N Na am me e field and a description of the NI CVS 1450 device in the D De es sc cr ri ip pt ti io on n field Note Device names are limited to 15 characters with no spaces or special characters The first and last letters must be alphanumeric F Click Next G If the network is configured to issue IP addresses using DHCP select Obtain IP Address from DHCP Server Ot...

Page 4: ...that hardware and software are properly installed to configure an IP address for the CVS 1450 device and to acquire an image Note These instructions are intended for basic installation and configuration Refer to the NI CVS 1450 Series User Manual and the application software documentation for detailed installation and configuration instructions National Instruments NI ni com and LabVIEW are tradem...

Page 5: ...r requirements D Plug the 4 position connector from the power supply into the power receptacle on the NI CVS 1450 device E Plug the power cord into the power supply F Plug the power cord into an outlet Once connected the NI CVS 1450 device runs a startup program that acquires images and displays them on the monitor These images verify that the hardware is properly connected Connect the NI CVS 1450...

Page 6: ...Module CD When the installation screen appears click Install LabVIEW Real Time Module and follow the setup instructions Install the NI Vision Development Module and NI IMAQ for IEEE 1394 Cameras C Insert the NI Vision Development Module CD When the installation screen appears click Install NI Vision Development Module and follow the setup instructions D When prompted insert the NI Vision Acquisiti...

Page 7: ...ured to issue IP addresses using DHCP select Obtain IP address from DHCP server Otherwise set the IP address manually by selecting Edit the IP settings Suggest Values and OK E Click Apply When prompted click Yes to restart the NI CVS 1450 device This initial installation process takes several minutes While the NI CVS 1450 device is restarting a red X appears next to the device name to indicate tha...

Page 8: ...the project and click Next C Select Add blank vi to target and click Next D Select the Networked option for Browse targets and click Browse E Select the Existing target or device option from Targets and Devices expand the Compact Vision System branch select your device and click OK F Click Next G Verify that the NI CVS 1450 device appears correctly in the LabVIEW Real Time Project and click F Fi i...

Reviews: