target automatically. You may also reboot the controller by right-clicking the
target name under 

Remote Systems

 and selecting 

Reboot

.

After rebooting the PXI controller, it appears in the

 Remote Systems

 category with the

assigned name.

6.

Expand the PXI controller view in the 

Remote Systems

 branch and select 

Software

.

7.

Click the 

Add/Remove Software

 button in the toolbar to launch the LabVIEW Real-

Time Software Wizard.

8.

Install the LabVIEW Real-Time software and device drivers that you require on the RT
target. Refer to the NI Web site at 

ni.com/info

 and enter the Info Code 

etspc

 for the

latest information about supported software.

After software installation, the controller automatically reboots, and you now can program it
using LabVIEW Real-Time.

Note

 

Refer to the 

RT Getting Started Guide

 on your host computer for more

information about setting up your RT target.

LabVIEW RT Configuration Switches

Use the LabVIEW RT configuration switches to configure LabVIEW RT if it is installed on
the controller. If you are not using LabVIEW RT, these switches should remain in the OFF
position. The controller reads these switches only after a system reset.

The NI PXI-8840 Quad-Core controller includes the following LabVIEW RT configuration
switches:

Switch 1—

Boot LabVIEW RT

: Set this switch to ON to boot LabVIEW RT.

Switch 2—

Boot Safe Mode

: Set this switch to ON to boot LabVIEW RT into safe mode

to reconfigure TCP/IP settings and to download or update software from a host computer.
This switch overrides the behavior of Switch 1. Booting the controller into safe mode
does not start the embedded LabVIEW RT engine. After changing the settings or
software, reboot the controller with this switch OFF to resume normal operation.

Switch 3—

Disable Startup VI

: Set this switch to ON to prevent VIs from automatically

running at startup if the controller becomes inaccessible because of a startup VI.

Switch 4—

Reset IP Address

: Set this switch to ON to reset the IP address and other

TCP/IP settings to their factory defaults. Use this switch if moving the controller to a
different subnet or if the current TCP/IP settings are valid.

Note

 

By default, the target automatically attempts to connect to the network using

DHCP. If the target cannot initiate a DHCP connection, the target connects to the
network with a link-local IP address or 

169.254.x.x.

The following figure shows the location of the LabVIEW RT configuration switches. The
switches are shown in the OFF position.

NI PXI-8840 Quad-Core Getting Started Guide

  | 

© National Instruments

  | 

7

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Summary of Contents for NI PXI-8840

Page 1: ...ized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In stock Re...

Page 2: ...re 8 Data Storage 8 NI PXI 8840 Quad Core Front Panel 9 Removing the NI PXI 8840 Quad Core from a PXI Chassis 11 Cleaning 11 Common Configuration Questions 11 General Questions 11 Boot Options 12 Cabl...

Page 3: ...y approved by National Instruments could void your authority to operate it under your local regulatory rules Caution To ensure the specified EMC performance operate this product only with shielded cab...

Page 4: ...C 60068 2 1 and IEC 60068 2 2 Meets MIL PRF 28800F Class 3 low temperature limit and MIL PRF 28800F Class 2 high temperature limit Relative humidity range 10 to 90 noncondensing Tested in accordance w...

Page 5: ...Quad Core 2 Remove any panels blocking access to the system controller slot Slot 1 in the chassis 3 Touch the metal part of the chassis case to discharge any static electricity that might be on your...

Page 6: ...ts offers a Y splitter adapter cable part number 778713 02 available through the online catalog at ni com products 11 Connect the DisplayPort monitor video cable to the DisplayPort connector or use th...

Page 7: ...Explorer MAX on another computer in the same subnet and expand the Remote Systems branch MAX lists the PXI controller as the controller model name followed by the MAC address for example NI PXI 8840 0...

Page 8: ...g LabVIEW RT configuration switches Switch 1 Boot LabVIEW RT Set this switch to ON to boot LabVIEW RT Switch 2 Boot Safe Mode Set this switch to ON to boot LabVIEW RT into safe mode to reconfigure TCP...

Page 9: ...s The drivers directory contains driver installers for the system peripherals These files and directories are copied exactly from the manufacturer distribution disks so the naming conventions vary fro...

Page 10: ...d variant only Front Panel Connectors The following table lists various peripherals and their corresponding NI PXI 8840 Quad Core external connectors bus interfaces and functions Peripheral External C...

Page 11: ...formation Front Panel Features The NI PXI 8840 Quad Core has the following front panel features A controller reset push button press the button to generate a reset to the controller Two front panel LE...

Page 12: ...s you may have when using an NI PXI 8840 Quad Core embedded controller General Questions What do the LEDs on the front panel mean Refer to the LED status descriptions in the Front Panel Features secti...

Page 13: ...r There are two methods Enter Setup and select the Boot menu You will see a list of all bootable devices ordered by device type You can set the boot order using and Set the order by device type and se...

Page 14: ...y PXI or VXI Controller at ni com support How do I install or reinstall the Ethernet driver Refer to KnowledgeBase 3H3COSD8 What Peripheral Drivers Should I Use with My PXI or VXI Controller at ni com...

Page 15: ...I 8840 Quad Core from the PXI chassis 2 Locate the DDR3L SO DIMM module on the side of the controller as shown in the following figure 3 Install the new DDR3L SO DIMM module into the slot NI PXI 8840...

Page 16: ...eBase 3H3COSD8 What Peripheral Drivers Should I Use with My PXI or VXI Controller at ni com support PXI Configuration How do I use the SMB trigger on the front panel Refer to the PXI Trigger Connectiv...

Page 17: ...hard drive on the controller Make sure the RAM is properly seated What If I Can t See The Video This problem usually results from having the video card output set past the monitor limits To resolve t...

Page 18: ...s that you can use to reset the CMOS 1 First Method a Enter the BIOS setup program as described in the Accessing BIOS Setup Utility section of the NI PXI 8840 Quad Core User Manual for more informatio...

Page 19: ...gistration facilitates technical support and ensures that you receive important information updates from NI A Declaration of Conformity DoC is our claim of compliance with the Council of the European...

Page 20: ...dial 1 866 ASK MYNI 275 6964 For telephone support outside the United States visit the Worldwide Offices section of ni com niglobal to access the branch office websites which provide up to date contac...

Page 21: ...ur NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and how to obtain relevant HTS codes ECCNs and other import export...

Page 22: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Reviews: