background image

© 2005–2015

 

National Instruments. All rights reserved. 

371608C-01

Jan15 

Refer to the 

NI Trademarks and Logo Guidelines 

at 

ni.com/trademarks

 for more information on National Instruments trademarks. Other 

product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National 
Instruments products/technology, refer to the appropriate location: 

Help»Patents

 in your software, the 

patents.txt

 file on your media, or the 

National Instruments Patents Notice

 at 

ni.com/patents

. You can find information about end-user license agreements (EULAs) and third-party 

legal notices in the readme file for your NI product. Refer to the 

Export Compliance Information 

at 

ni.com/legal/export-compliance

 

for the National Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES 
NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR 
ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable 
limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015.

Where to Go for Support

The National Instruments website is your complete resource for technical support. At 

ni.com/

support

 you have access to everything from troubleshooting and application development 

self-help resources to email and phone assistance from NI Application Engineers.

Visit 

ni.com/services

 for NI Factory Installation Services, repairs, extended warranty, and 

other services.

Visit 

ni.com/register

 to register your National Instruments product. Product registration 

facilitates technical support and ensures that you receive important information updates from NI. 

A Declaration of Conformity (DoC) is our claim of compliance with the Council of the European 
Communities using the manufacturer’s declaration of conformity. This system affords the user 
protection for electromagnetic compatibility (EMC) and product safety. You can obtain the DoC 
for your product by visiting 

ni.com/certification

. If your product supports calibration, 

you can obtain the calibration certificate for your product at 

ni.com/calibration

.

National Instruments corporate headquarters is located at 11500 North Mopac Expressway, 
Austin, Texas, 78759-3504. National Instruments also has offices located around the world. For 
telephone support in the United States, create your service request at 

ni.com/support

 or dial 

1 866 ASK MYNI (275 6964). For telephone support outside the United States, visit the 
Worldwide Offices section of 

ni.com/niglobal

 to access the branch office websites, which 

provide up-to-date contact information, support phone numbers, email addresses, and current 
events.

Summary of Contents for NI PXI-5922

Page 1: ...libration 2 External Calibration 2 Calibration Intervals 2 Software and Documentation 2 Documentation 4 Self Calibration Procedures 4 MAX 5 Scope SFP 5 NI SCOPE 5 External Calibration Options 6 Comple...

Page 2: ...nsate for environmental changes Caution Although you can use self calibration repeatedly self calibrating the NI 5922 more than a few times a day may cause excessive wear on the relays over time The m...

Page 3: ...cription IVI Bin niscope_32 dll NI SCOPE driver containing the entire NI SCOPE API including calibration functions IVI Lib msc niscope lib NI SCOPE library for Microsoft C containing the entire NI SCO...

Page 4: ...Self calibrate the oscilloscope before you perform verification NI SCOPE includes self calibration example programs for LabVIEW CVI and Microsoft Visual C You can initiate self calibration using Meas...

Page 5: ...o the oscilloscope 2 Launch the Scope SFP by selecting Start Programs National Instruments NI SCOPE Scope Soft Front Panel 3 Select the device you want to calibrate using the Select Device dialog box...

Page 6: ...to limits given in Tables 3 through 7 This document provides two sets of test limits for most verification stages the calibration test limits and the published specifications The calibration test lim...

Page 7: ...ication fall within the calibration test limits the device is guaranteed to meet or exceed its published specifications for a full calibration interval In this case you can update the calibration date...

Page 8: ...gure 2 Optional Calibration Programming Flow Self Calibrate Verify Yes No Meets Published Specifications Yes Results Within Published Specs Adjustment Optional No Adjust Cal Dates and Temperatures Upd...

Page 9: ...extra noise that can affect measurements Keep relative humidity between 10 and 90 non condensing Maintain an ambient temperature of 23 5 C Allow a warm up time of at least 15 minutes after NI SCOPE l...

Page 10: ...is section begin with niScope_init niScope Initialize VI with resetDevice set to NISCOPE_VAL_TRUE and end with niScope_close niScope Close VI If any of these tests fail immediately after you perform a...

Page 11: ...hat corresponds to the vertical range used If the result is within the selected test limit the device has passed this portion of the verification 7 Repeat steps 1 through 6 for each iteration in Table...

Page 12: ...r vi The instrument handle you obtained from niScope_init 6 Call niScope_FetchArrayMeasurement niScope Fetch Array Measurement VI with the following parameters channelList 0 timeout 5 0 arrayMeasFunct...

Page 13: ...st 0 inputImpedance NISCOPE_VAL_50_OHM maxInputFrequency 0 3 Call niScope_ConfigureVertical niScope Configure Vertical VI with the following parameters channelList 0 range 2 offset 0 0 coupling NISCOP...

Page 14: ...the following parameters channelList 0 inputImpedance NISCOPE_VAL_1_MEG_OHM maxInputFrequency 0 8 Call niScope_InitiateAcquisition niScope Initiate Acquisition VI with the following parameter vi The...

Page 15: ...t 0 0 coupling NISCOPE_VAL_DC probeAttenuation 1 0 enabled NISCOPE_VAL_TRUE 3 Call niScope_ConfigureHorizontalTiming niScope Configure Horizontal Timing VI with the following parameters minSampleRate...

Page 16: ...a percentage of input using the following formula where a the measured positive voltage b the measured negative voltage c the applied positive voltage d the applied negative voltage Compare the resul...

Page 17: ...ing niScope Configure Horizontal Timing VI with the following parameters minSampleRate 15 000 000 minNumPts 1 000 000 refPosition 50 0 numRecords 1 enforceRealtime NISCOPE_VAL_TRUE 4 Call niScope_Comm...

Page 18: ...ion date and temperature in the EEPROM of the oscilloscope Note If the oscilloscope passed the entire verification procedure within the calibration test limits and you do not want to perform an adjust...

Page 19: ...le 10 Call niScope_CalAdjustRange niScope Cal Adjust Range VI with the following parameters channelName 1 range 0 stimulus 4 0 11 Disconnect or disable all inputs to the oscilloscope 12 Call niScope_C...

Page 20: ...nformation from My System Devices and Interfaces 2 Select the Calibration tab You should see information about the last date and temperature for both external and self calibration NI SCOPE NI SCOPE pr...

Page 21: ...is your complete resource for technical support At ni com support you have access to everything from troubleshooting and application development self help resources to email and phone assistance from...