Appendix B

Pinouts

©

 National Instruments Corporation

B-3

NI PXI-1031/PXI-1031DC User Manual

 

Table B-2.  

P2 (J2) Connector Pinout for the System Controller Slot

Pin

Z

A

B

C

D

E

F

22

GND

GA4

GA3

GA2

GA1

GA0

GND

21

GND

CLK6

GND

RSV

RSV

RSV

GND

20

GND

CLK5

GND

RSV

GND

RSV

GND

19

GND

GND

GND

RSV

RSV

RSV

GND

18

GND

PXI_TRIG3

PXI_TRIG4

PXI_TRIG5

GND

PXI_TRIG6

GND

17

GND

PXI_TRIG2

GND

RSV

REQ6#

GNT6#

GND

16

GND

PXI_TRIG1

PXI_TRIG0

RSV

GND

PXI_TRIG7

GND

15

GND

PXI_BRSVA15

GND

RSV

REQ5#

GNT5#

GND

14

GND

AD[35]

AD[34]

AD[33]

GND

AD[32]

GND

13

GND

AD[38]

GND

V(I/O)

AD[37]

AD[36]

GND

12

GND

AD[42]

AD[41]

AD[40]

GND

AD[39]

GND

11

GND

AD[45]

GND

V(I/O)

AD[44]

AD[43]

GND

10

GND

AD[49]

AD[48]

AD[47]

GND

AD[46]

GND

9

GND

AD[52]

GND

V(I/O)

AD[51]

AD[50]

GND

8

GND

AD[56]

AD[55]

AD[54]

GND

AD[53]

GND

7

GND

AD[59]

GND

V(I/O)

AD[58]

AD[57]

GND

6

GND

AD[63]

AD[62]

AD[61]

GND

AD[60]

GND

5

GND

C/BE[5]#

GND

V(I/O)

C/BE[4]#

PAR64

GND

4

GND

V(I/O)

PXI_BRSVB4

C/BE[7]#

GND

C/BE[6]#

GND

3

GND

CLK4

GND

GNT3#

REQ4#

GNT4#

GND

2

GND

CLK2

CLK3

SYSEN#

GNT2#

REQ3#

GND

1

GND

CLK1

GND

REQ1#

GNT1#

REQ2#

GND

Summary of Contents for NI PXI-1031

Page 1: ...1 162 Wroc aw Poland biuro rgbelektronika pl 48 71 325 15 05 www rgbautomatyka pl www rgbelektronika pl DATASHEET www rgbautomatyka pl www rgbelektronika pl OTHER SYMBOLS NI PXI 8175 NIPXI8175 NIPXI 8...

Page 2: ...d with a wide variety of tools and having several testing stands at their disposal are a guarantee of the highest quality service OUR SERVICES ENCODERS SERVO DRIVERS LINEAR ENCODERS SERVO AMPLIFIERS C...

Page 3: ...PXI NI PXI 1031 PXI 1031DC User Manual NI PXI 1031 PXI 1031DC User Manual October 2004 371226B 01...

Page 4: ...1190000 Israel 972 0 3 6393737 Italy 39 02 413091 Japan 81 3 5472 2970 Korea 82 02 3451 3400 Malaysia 603 9131 0918 Mexico 01 800 010 0793 Netherlands 31 0 348 433 466 New Zealand 0800 553 322 Norway...

Page 5: ...gent acts and power failure or surges fire flood accident actions of third parties or other events outside reasonable control Copyright Under the copyright laws this publication may not be reproduced...

Page 6: ...PXI 1031 PXI 1031DC Backplane Overview 1 6 Interoperability with CompactPCI 1 6 System Controller Slot 1 6 Star Trigger Slot 1 7 Peripheral Slots 1 7 Local Bus 1 7 Trigger Bus 1 8 System Reference Cl...

Page 7: ...Configuration in MAX 2 11 Using System Configuration and Initialization Files 2 11 Chapter 3 Maintenance DC Fuse Replacement PXI 1031DC Only 3 1 Service Interval 3 1 Preparation 3 1 Cleaning 3 2 Inter...

Page 8: ...data loss or a system crash When this symbol is marked on the product refer to the Read Me First Safety and Radio Frequency Interference document shipped with the product for precautions to take bold...

Page 9: ...al NI PXI 1031DC DC Cable Kit Installation Guide CompactPCI Specification PICMG 2 0 R 3 0 PXI Hardware Specification PXI Software Specification IEEE 1101 1 1991 IEEE Standard for Mechanical Core Speci...

Page 10: ...handles hardware and switches are undamaged Inspect the inner chassis for any possible damage debris or detached components If damage appears to have been caused during shipment file a claim with the...

Page 11: ...mum usability in a wide range of applications The key features of the chassis include the following Accepts 3U PXI and CompactPCI PICMG 2 0 R 3 0 modules 4 slot chassis with universal AC input and aut...

Page 12: ...chassis name stenciled on the face plate Figure 1 2 shows the rear view of the PXI 1031 Figure 1 3 shows the rear panel of the PXI 1031DC Figure 1 4 shows the bottom of the chassis both types of chas...

Page 13: ...upply Fan Exhaust 4 Chassis Ground Screw 5 Fan Speed Selector Switch 6 Rubber Foot 1 Rear Exhaust Vents 2 DC Fuse Socket 3 DC Input 4 AC Input 5 Power Supply Fan Exhaust 6 Chassis Ground Screw 7 AUTO...

Page 14: ...assis EMC Filler Panels Optional EMC filler panel kits are available from National Instruments Rack Mount Kits A rack mount kit option is available for mounting the PXI 1031 or PXI 1031DC chassis into...

Page 15: ...f the CompactPCI specification for both peripheral and system modules Refer to Appendix B Pinouts for pinout information The PXI specific signals are on the backplane P2 connectors and are found only...

Page 16: ...ference Clock section Peripheral Slots There are three peripheral slots including the star trigger slot Local Bus The PXI backplane local bus is a daisy chained bus that connects each peripheral slot...

Page 17: ...1031 PXI 1031DC supplies the PXI 10 MHz system clock signal PXI_CLK10 independently to each peripheral slot An independent buffer having a source impedance matched to the backplane and a skew of less...

Page 18: ...requires a connection from the premise wire safety ground to the chassis ground The earth safety ground must be connected during use of this equipment to minimize shock hazards Refer to the Connectin...

Page 19: ...roviding Adequate Clearance Apertures in the top bottom front rear and along the right side of the chassis facilitate power supply and module cooling Air enters through filters and fan inlet in the bo...

Page 20: ...rear panel of the PXI 1031 and PXI 1031DC Refer to Figure 1 2 Rear View of the PXI 1031 Chassis or Figure 1 3 Rear View of the PXI 1031DC Chassis to locate the fan speed selector switch Select HIGH fo...

Page 21: ...fety ground For DC powered applications or if your power outlet does not have an appropriate ground connection you must connect the premise safety ground to the chassis grounding screw located on the...

Page 22: ...ce it in standby mode Press the power switch to the On position if not already on Observe that all fans become operational Connecting to a DC Power Source PXI 1031DC Only For full chassis power the DC...

Page 23: ...NI PXI 1031DC DC Cable Kit Installation Guide for information on fuse installation Note You can purchase an optional DC cable from National Instruments that incorporates an in line fuse and the mating...

Page 24: ...as shown in Figure 2 3 Figure 2 3 Injector Ejector Handle Position during Controller or Peripheral Module Insertion 3 When you begin to feel resistance push up on the injector ejector handle to inject...

Page 25: ...power switch is in the Off Standby position 2 Install a module into a chassis slot by first placing the module card edges into the front module guides top and bottom as shown in Figure 2 5 Slide the...

Page 26: ...mation Explorer MAX included on the NI Driver CD ROM packaged with your kit MAX creates the pxisys ini file that defines the layout and parameters of your PXI system After installing the software on t...

Page 27: ...ght click this entry to display the context menu and then select the appropriate controller model from the Identify As submenu 4 Click the PXI System controller and the chassis or multiple chassis in...

Page 28: ...nfigured by programs such as NI DAQmx This prevents the instruments from double driving the trigger lines possibly damaging devices in the chassis Complete the following steps to reserve these trigger...

Page 29: ...he system controller or provides a utility that can read an arbitrary chassis ini file and generate the corresponding pxisys ini file System controllers from National Instruments use MAX to generate t...

Page 30: ...maximum interval of six months Depending on the amount of use and ambient dust levels in the operating environment the filter may require more frequent cleaning Clean dust from the chassis exterior an...

Page 31: ...not wash the front or rear panel connectors or switches Cover these components while cleaning the chassis Do not use harsh chemical cleaning agents they may damage the chassis Avoid chemicals that con...

Page 32: ...he fan filter by washing it in a mild soap solution and then vacuuming or blowing air through it Rinse the filter with water and allow it to dry before reinstalling it on the chassis You can replace t...

Page 33: ...be impaired Note Specifications are subject to change without notice This appendix contains specifications for the PXI 1031 and PXI 1031DC chassis PXI 1031 Chassis Electrical AC Input Input voltage ra...

Page 34: ...current capacity IMP Over current protection All outputs protected from short circuit and overload Overvoltage protection 114 to 145 above nominal output voltage Chassis Cooling Per slot cooling capac...

Page 35: ...onment Ambient temperature range 0 to 50 C Tested in accordance with IEC 60068 2 1 and IEC 60068 2 2 Relative humidity range 10 to 90 noncondensing Tested in accordance with IEC 60068 2 56 Storage Env...

Page 36: ...issions Sound Pressure Level at Operator Position Tested in accordance with ISO 7779 PXI 1031 Auto fan at 25 C ambient 40 7 dBA High fan 49 4 dBA Sound Power Tested in accordance with ISO 7779 PXI 103...

Page 37: ...ct The front panel power switch controls the internal chassis power supply that provides DC power to the CompactPCI PXI backplane DC Input Input voltage range 11 30 VDC Input current rating 30 A maxim...

Page 38: ...145 6 W Overcurrent protection All outputs protected from short circuit and overload Overvoltage protection All outputs protected from overvoltage Cycle the primary power and front power switch to res...

Page 39: ...th IEC 60068 2 1 and IEC 60068 2 2 Relative humidity range 10 to 90 noncondensing Tested in accordance with IEC 60068 2 56 Storage Environment Ambient temperature range 20 to 70 C Tested in accordance...

Page 40: ...tor Position Tested in accordance with ISO 7779 PXI 1031DC Auto fan at 25 C ambient 45 5 dBA High fan 49 4 dBA Sound Power Tested in accordance with ISO 7779 PXI 1031DC Auto fan at 25 C ambient 54 3 d...

Page 41: ...be installed CE Compliance This product meets the essential requirements of applicable European Directives as amended for CE marking as follows Low Voltage Directive safety 73 23 EEC Electromagnetic C...

Page 42: ...over the operating temperature range Mechanical Overall dimensions standard chassis Height 177 mm 6 97 in Note 12 7 mm 0 50 in is added to height when feet are installed Width 257 1 mm 10 12 in Depth...

Page 43: ...XI 1031 PXI 1031DC dimensions The holes shown are for the installation of the optional rack mount kits as shown in Figure A 3 Notice that the front and rear rack mounting holes size M4 are symmetrical...

Page 44: ...Appendix A Specifications NI PXI 1031 PXI 1031DC User Manual A 12 ni com Figure A 2 PXI 1031 PXI 1031DC Dimensions Bottom in Inches mm 8 816 223 93 659 16 74 6 578 167 08 857 21 77...

Page 45: ...struments Corporation A 13 NI PXI 1031 PXI 1031DC User Manual Figure A 3 shows the PXI 1031 PXI 1031DC rack mount kit components Figure A 3 PXI 1031 PXI 1031DC Rack Mount Kit Components 1 PXI 1031 PXI...

Page 46: ...ut for the System Controller slot Table B 2 shows the P2 J2 connector pinout for the System Controller slot Table B 3 shows the P1 J1 connector pinout for the star trigger slot Table B 4 shows the P2...

Page 47: ...15 AD 14 GND AD 13 GND 18 GND SERR GND 3 3V PAR C BE 1 GND 17 GND 3 3V SDONE SBO GND PERR GND 16 GND DEVSEL GND V I O STOP LOCK GND 15 GND 3 3V FRAME IRDY GND TRDY GND 12 14 Key Area 11 GND AD 18 AD 1...

Page 48: ...PXI_TRIG0 RSV GND PXI_TRIG7 GND 15 GND PXI_BRSVA15 GND RSV REQ5 GNT5 GND 14 GND AD 35 AD 34 AD 33 GND AD 32 GND 13 GND AD 38 GND V I O AD 37 AD 36 GND 12 GND AD 42 AD 41 AD 40 GND AD 39 GND 11 GND AD...

Page 49: ...AD 14 GND AD 13 GND 18 GND SERR GND 3 3V PAR C BE 1 GND 17 GND 3 3V SDONE SBO GND PERR GND 16 GND DEVSEL GND V I O STOP LOCK GND 15 GND 3 3V FRAME IRDY GND TRDY GND 12 14 Key Area 11 GND AD 18 AD 17 A...

Page 50: ...G1 PXI_TRIG0 RSV GND PXI_TRIG7 GND 15 GND PXI_BRSVA15 GND RSV PXI_STAR6 PXI_LBR6 GND 14 GND AD 35 AD 34 AD 33 GND AD 32 GND 13 GND AD 38 GND V I O AD 37 AD 36 GND 12 GND AD 42 AD 41 AD 40 GND AD 39 GN...

Page 51: ...15 AD 14 GND AD 13 GND 18 GND SERR GND 3 3V PAR C BE 1 GND 17 GND 3 3V SDONE SBO GND PERR GND 16 GND DEVSEL GND V I O STOP LOCK GND 15 GND 3 3V FRAME IRDY GND TRDY GND 12 14 Key Area 11 GND AD 18 AD 1...

Page 52: ...RIG1 PXI_TRIG0 RSV GND PXI_TRIG7 GND 15 GND PXI_BRSVA15 GND RSV PXI_LBL6 PXI_LBR6 GND 14 GND AD 35 AD 34 AD 33 GND AD 32 GND 13 GND AD 38 GND V I O AD 37 AD 36 GND 12 GND AD 42 AD 41 AD 40 GND AD 39 G...

Page 53: ...nal Instruments Application Engineers make sure every question receives an answer For information about other technical support options in your area visit ni com services or contact your local office...

Page 54: ...ni com calibration If you searched ni com and could not find the answers you need contact your local office or NI corporate headquarters Phone numbers for our worldwide offices are listed at the fron...

Page 55: ...e p pico 10 12 n nano 10 9 micro 10 6 m milli 10 3 k kilo 103 M mega 106 G giga 109 T tera 1012 Symbols Degrees Equal or greater than Equal or less than Percent Ohms A A Amperes AC Alternating current...

Page 56: ...CI It uses industry standard mechanical components and high performance connector technologies to provide an optimized system intended for rugged applications It is electrically compatible with the PC...

Page 57: ...agnetic Compatibility EMI Electromagnetic Interference F FCC Federal Communications Commission filler panel A blank module front panel used to fill empty slots in the chassis G g 1 grams 2 a measure o...

Page 58: ...egulation The maximum steady state percentage that a DC voltage output will change as a result of a step change from no load to full load output current M m Meters MAX NI Measurement Automation Explor...

Page 59: ...Nanosecond one billionth of a second 10 9 P ppm Parts per million PXI PCI eXtensions for Instrumentation PXI is an implementation of CompactPCI with added electrical features that meet the high perfor...

Page 60: ...l slots in the chassis as well as a BNC connector on the rear of chassis labeled 10 MHz REF OUT The system reference clock can be used for synchronization of multiple modules in a measurement or contr...

Page 61: ...ne 1 6 configuration See installation configuration and operation conventions used in the manual vii cooling air cooling of PXI 1031 2 2 air cooling of PXI 1031DC 2 2 air intake figure 2 3 filler pane...

Page 62: ...resources C 1 interoperability with CompactPCI 1 6 K key features 1 2 KnowledgeBase C 1 L local bus routing figure 1 7 star trigger and local bus routing figure 1 8 M maintenance of PXI 1031 3 1 clea...

Page 63: ...7 star trigger ST slot 1 7 system reference clock 1 8 trigger bus 1 8 fan speed setting 2 3 front view figure 1 3 installation See installation configuration and operation key features 1 2 maintenanc...

Page 64: ...ironmental A 3 specifications PXI 1031DC acoustic emissions A 8 sound power A 8 sound pressure level at operator position A 8 chassis cooling A 6 electrical AC input A 4 DC input A 5 DC output A 5 env...

Reviews: