2.
Align the cRIO-9035 on the surface.
3.
Fasten the cRIO-9035 to the surface using the M4 screws appropriate for the surface.
Screws must not exceed 8 mm of insertion into the cRIO-9035. Tighten the screws to a
maximum torque of 1.3 N · m (11.5 lb · in.).
Surface Mounting Dimensions
The following figure shows the surface mounting dimensions for the cRIO-9035.
Figure 14. cRIO-9035 Surface Mounting Dimensions
3×
23.7 mm (0.94 in.)
3×
20.3 mm (0.80 in.)
3×
20.3 mm (0.80 in.)
120 mm (4.72 in.)
9× ISO M4 × 0.7 Thread
8 mm Maximum Insertion Depth
120 mm (4.72 in.)
14.8 mm (0.59 in.)
Mounting the cRIO-9035 on a Panel
You can use the NI panel mounting kit to mount the cRIO-9035 on a panel.
What to Use
•
cRIO-9035
•
Screwdriver, Phillips #2
•
NI panel mounting kit, 157253-01
–
Panel mounting plate
–
M4 x 10 screws (x6)
What to Do
Complete the following steps to mount the cRIO-9035 on a panel.
28
|
ni.com
|