![National Instruments NI cDAQ-9181 User Manual Download Page 38](http://html1.mh-extra.com/html/national-instruments/ni-cdaq-9181/ni-cdaq-9181_user-manual_3435125038.webp)
© National Instruments
|
1-29
NI cDAQ-9181/9184/9188/9191 User Manual
Ethernet Cabling
Table 1-6 shows the shielded Ethernet cable wiring connections for both straight through and
crossover cables.
Table 1-6.
Ethernet Cable Wiring Connections
Pin
Connector 1
Connector 2
Straight Through
Crossover
1
white/orange
white/orange
white/green
2
orange
orange
green
3
white/green
white/green
white/orange
4
blue
blue
blue
5
white/blue
white/blue
white/blue
6
green
green
orange
7
white/brown
white/brown
white/brown
8
brown
brown
brown
Connector 1
Connector 2
Pin 1
Pin 1
Pin
8
Pin
8