National Instruments NI 9866 Getting Started Download Page 9

Note

 For safety certifications, refer to the product label or the 

Product

Certifications and Declarations

 section.

Hazardous Locations

U.S. (UL)

Class I, Division 2, Groups A, B, C, D, T4; Class I, Zone 2, AEx nA IIC T4 Gc

Canada (C-UL)

Class I, Division 2, Groups A, B, C, D, T4; Class I, Zone 2, Ex nA IIC T4

Europe (DEMKO) Ex nA IIC T4 Gc

Environmental

Refer to the manual for the chassis you are using for more information about

meeting these specifications.

Operating temperature (IEC 60068-2-1, IEC 60068-2-2)

-40 °C to 70 °C

Storage temperature (IEC 60068-2-1, IEC 60068-2-2)

-40 °C to 85 °C

Ingress protection

IP40

Operating humidity (IEC 60068-2-30)

10% RH to 90% RH, noncondensing

Storage humidity (IEC 60068-2-30)

5% RH to 95% RH, noncondensing

Pollution Degree

2

Maximum altitude

2,000 m

Indoor use only.

Shock and Vibration

To meet these specifications, you must panel mount the system.

Operating vibration

Random

5 g RMS, 10 Hz to 500 Hz

Sinusoidal

5 g, 10 Hz to 500 Hz

© National Instruments

9

NI-9866 Getting Started

Summary of Contents for NI 9866

Page 1: ...NI 9866 Getting Started 2022 07 06...

Page 2: ...esistors 6 NI 9866 Hardware Overview 6 NI 9866 Specifications 7 LIN Characteristics 7 Power Requirements 7 Physical Characteristics 7 Safety Voltages 8 Safety Compliance and Hazardous Locations Standa...

Page 3: ...n Using the product in a manner not specified can damage the product and compromise the built in safety protection Attention Suivez toutes les instructions et respectez toutes les mises en garde de la...

Page 4: ...e and Internationally The NI 9866 has been evaluated as Ex nA IIC T4 Gc equipment under DEMKO 07ATEX 0626664X and is IECEx UL 14 0089X certified Each NI 9866 is marked II 3G and is suitable for use in...

Page 5: ...und for LIN signal You can connect the LIN bus reference ground to one or both COM pins The port also has an optional shield pin SHLD that you can connect to a shielded LIN cable Connecting SHLD may i...

Page 6: ...nts and should be suitable for most applications Cable Lengths The maximum allowable cable length is 40 m per the LIN specification Number of LIN Devices The maximum number of devices on a LIN bus is...

Page 7: ...xt Pwr Supply Required Rx Tx LIN Controller LIN LIN Transceiver Rx Tx COM Vsup _ NI 9866 Specifications The following specifications are typical for the range 40 C to 70 C unless otherwise noted LIN C...

Page 8: ...to earth ground Withstand 1 000 V RMS verified by a 5 s dielectric withstand test Continuous 60 V DC Measurement Category I Safety Compliance and Hazardous Locations Standards This product is designe...

Page 9: ...information about meeting these specifications Operating temperature IEC 60068 2 1 IEC 60068 2 2 40 C to 70 C Storage temperature IEC 60068 2 1 IEC 60068 2 2 40 C to 85 C Ingress protection IP40 Opera...

Page 10: ...ct Certification section Note For EMC compliance operate this product according to the documentation CE Compliance 2014 34 EU Potentially Explosive Atmospheres ATEX Product Certifications and Declarat...

Page 11: ...e RoHS NI RoHS NI RoHS ni com environment rohs_china For information about China RoHS compliance go to ni com environment rohs_china NI Services Visit ni com support to find support resources includin...

Reviews: