![National Instruments NI 9505E Operating Instructions And Specifications Download Page 11](http://html1.mh-extra.com/html/national-instruments/ni-9505e/ni-9505e_operating-instructions-and-specifications_3449846011.webp)
NI 9505E Operating Instructions and Specifications
10
ni.com
V
SUP
The V
SUP
LED (green) illuminates when the motor DC power
supply is properly connected and powering the drive.
Disable
The Disable LED (yellow) illuminates when the drive is disabled.
The drive is disabled by default at power-on. You can enable the
drive using the
Enable Drive
method in software. Refer to the
NI 9505 Reference Help
book in the
LabVIEW Help
, available
by selecting
Help»Search the LabVIEW Help
, for more
information about this method.
Fault
Caution
If the Fault LED is lit, determine the cause of the
fault and correct it before enabling the drive.
The Fault LED (red) illuminates when a fault occurs. A fault
disables the drive. Causes for fault are the following:
Caution
V
SUP
greater than 40 V will result in damage to
the NI 9505E.
•
Overvoltage
•
Undervoltage