Load

NI 9260

with mini XLR

AO+

AO–

IN+

IN–

CHASSIS
GND

3

2

1

Note

 You can only use the NI-9260 with mini XLR with differential

instruments.

Notice

 Do not connect AO- to chassis ground on the NI-9260 with mini

XLR. Connecting this pin to chassis ground will short circuit the output.

Notice

 Do not connect the NI-9260 with mini XLR to a ground referenced

single-ended instrument. Refer to the Circuitry section in the device

datasheet on 

ni.com/manuals

 for further information.

NI 9260 with BNC Analog Output Connections

NI 9260 with BNC

Load

AO+

AO–

IN+

IN–/GND

50 

Ω

NI-9260 Connection Guidelines

 Make sure that devices you connect to the NI-9260 are compatible with the

module specifications.

To minimize ground noise, make sure you connect the chassis ground to

earth ground.

Overvoltage Protection

The NI-9260 provides overvoltage protection for each channel.

ni.com

8

NI-9260 Getting Started

Summary of Contents for NI-9260

Page 1: ...NI 9260 Getting Started 2022 07 12...

Page 2: ...zardous Locations 4 Electromagnetic Compatibility Guidelines 6 Preparing the Environment 6 NI 9260 Pinout 7 NI 9260 with mini XLR Analog Output Connection 7 NI 9260 with BNC Analog Output Connections...

Page 3: ...fety ratings Refer to the documentation for each component in the system to determine the safety and EMC ratings for the entire system Safety Guidelines Caution Observe all instructions and cautions i...

Page 4: ...d from human contact Caution When module terminals are hazardous voltage LIVE 42 4 Vpk 60 V DC you must ensure that devices and circuits connected to the module are properly insulated from human conta...

Page 5: ...locations in ambient temperatures of 40 C Ta 70 C If you are using the NI 9260 in Gas Group IIC hazardous locations you must use the device in an NI chassis that has been evaluated as Ex nC IIC T4 Ex...

Page 6: ...in the product documentation Furthermore any changes or modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory...

Page 7: ...manuals for complete specifications NI 9260 Pinout CHASSIS GND AO0 AO0 AO0 AO0 AO1 AO1 CHASSIS GND A10 A10 Signal Description AO Positive analog output signal connection AO Negative analog output sign...

Page 8: ...erenced single ended instrument Refer to the Circuitry section in the device datasheet on ni com manuals for further information NI 9260 with BNC Analog Output Connections NI 9260 with BNC Load AO AO...

Page 9: ...it ni com support to find support resources including documentation downloads and troubleshooting and application development self help such as tutorials and examples Visit ni com services to learn ab...

Reviews: