background image

Operating temperature (IEC 60068-2-1, IEC 60068-2-2)

-40 °C to 70 °C

Operating humidity (IEC 60068-2-30)

10% RH to 90% RH, noncondensing

Pollution Degree

2

Maximum altitude

5,000 m

Indoor use only.

Note

 Refer to the NI-9230 Specifications on 

ni.com/manuals

 for

complete specifications.

Connecting the NI-9230

The NI-9230 provides connections to three simultaneously sampled analog input

channels.

Figure 2. NI-9230 Pinout

AI0+

AI0–

AI1+

AI1–

AI2+

AI2–

0

1

0

1

0

1

AI0–
AI0+

AI1–
AI1+

AI2–
AI2+

Note

 You must use 2-wire ferrules to create a secure connection when

connecting more than one wire to a single terminal on the NI-9230 with

screw terminal.

Each channel has a terminal to which you can connect a signal source. The AI+

terminal of the connector provides the DC excitation, when enabled, and the

positive input signal connection. The AI- terminal provides the excitation return

path and the signal ground reference.

ni.com

8

NI-9230 Getting Started

Summary of Contents for NI-9230

Page 1: ...NI 9230 Getting Started 2022 07 06...

Page 2: ...in Europe and Internationally 4 Electromagnetic Compatibility Guidelines 5 Cable Requirements for EMC Compliance 6 Special Conditions for Marine Applications 7 Preparing the Environment 7 Connecting t...

Page 3: ...tings Refer to the documentation for each component in the system to determine the safety and EMC ratings for the entire system Safety Guidelines Caution Observe all instructions and cautions in the u...

Page 4: ...may result in serious injury or death Caution Do not disconnect I O side wires or connectors unless power has been switched off or the area is known to be nonhazardous Caution Do not remove modules un...

Page 5: ...all only be used in an area of not more than Pollution Degree 2 as defined in IEC EN 60664 1 Caution The system shall be mounted in an ATEX IECEx certified enclosure with a minimum ingress protection...

Page 6: ...orts and connected to the product using a shielded cable If unshielded cables or accessories are not properly installed and shielded the EMC specifications for the product are no longer guaranteed Cau...

Page 7: ...e Signal Source Signal Source Ferrite Ferrite Special Conditions for Marine Applications Some products are approved for marine shipboard applications To verify marine approval certification for a prod...

Page 8: ...analog input channels Figure 2 NI 9230 Pinout AI0 AI0 AI1 AI1 AI2 AI2 0 1 0 1 0 1 AI0 AI0 AI1 AI1 AI2 AI2 Note You must use 2 wire ferrules to create a secure connection when connecting more than one...

Page 9: ...protection Figure 3 Connecting a Grounded Signal Source NI 9230 AI AI Signal Source Common Mode Voltage Figure 4 Connecting a Floating Signal Source NI 9230 AI AI Signal Source Integrated Electronic P...

Page 10: ...h as tutorials and examples Visit ni com services to learn about NI service offerings such as calibration options repair and replacement Visit ni com register to register your NI product Product regis...

Reviews: