Table 6.
USB Device Port Cable
Cable
Length
Part Number
NI Locking USB Cable
1 m
157788-01
Buttons
The NI 9149 provides the following buttons.
Figure 2.
NI 9149 Buttons
1
1. RESET Button
RESET Button
Press the RESET button to reset the processor in the same manner as cycling power.
Troubleshooting Network Connectivity
You can use the RESET button to troubleshoot network connectivity.
Complete the following steps to reset the network adapters to default settings.
1.
Hold the RESET button for 5 seconds, and then release it to boot the controller in safe
mode and enable Console Out.
2.
Hold the RESET button again for 5 seconds to boot the controller into safe mode, enable
Console Out, and reset network adapters to default settings.
NI 9149 User Manual
|
© National Instruments
|