3-2
|
ni.com
Chapter 3
Counters
counter sample clock. You can route an external signal or one of many different internal signals
as the sample clock. For example, you can generate a signal using one counter and route that
signal to the sample clock of another counter. Refer to Chapter 5,
, for more information about which signals can be used as the source.
Counter Input Applications
The following sections list the various counter input applications available:
•
•
•
•
•
•
•
Edge Counting
In an Edge Counting measurement task, the counter counts the number of active edges of a
signal. Figure 3-2 shows an example of edge counting.
Figure 3-2.
Edge Counting
Channel Settings
By default, the counter:
•
starts the count at 0.
•
counts edges on a default PFI terminal. Refer to Chapter 5,
, for more information.
•
counts rising edges.
•
counts up always.
You can change these behaviors by configuring DAQmx Channel properties:
•
CI.CountEdges.InitialCnt
—To specify the initial value of the count.
•
CI.CountEdges.Term
—The signal-to-measure comes from an input terminal. To change
the signal-to-measure, specify a different terminal via this property.