A-6
|
ni.com
Appendix A
Specifications
Dimensions .......................................................11.77 cm × 8.58 cm × 5.06 cm
(4.63 in. × 3.38 in. × 1.99 in.)
Weight ...............................................................525 g (18.52 oz)
Environmental
The NI Smart Camera is intended for indoor use only.
Operating temperature
Ambient temperature ................................0 to 45 °C
Maximum camera housing temperature ...65 °C
Storage temperature ..........................................-15 to 45 °C
Humidity ...........................................................10% to 90% RH, noncondensing
IP rating.............................................................40
Pollution degree ................................................2
Operating shock (IEC 60068-2-27) ..................50 g, 3 ms half sine, 18 shocks at 6 orientations;
30 g, 11 ms half sine, 18 shocks at 6 orientations
Operating vibration
Random (IEC 60068-2-34) .......................10 Hz to 500 Hz, 10 Grms, 100 min per axis
Swept sine (IEC 60068-2-6) .....................10 Hz to 500 Hz, 10 g
Approved at altitudes up to 2,000 m.
Safety
The NI Smart Camera meets the requirements of the following standards for safety and electrical
equipment for measurement, control, and laboratory use:
•
IEC 61010-1, EN 61010-1
•
UL 61010-1, CSA 61010-1
Note
For UL and other safety certifications, refer to the product label or visit
ni.com/certification
, search by model number or product line, and click the
appropriate link in the Certification column.
Electromagnetic Compatibility
The NI Smart Camera meets the following standards of EMC for electrical equipment for
measurement, control, and laboratory use:
•
EN 61326 EMC requirements; Minimum Immunity
•
EN 55011 Emissions; Group 1, Class A
•
CE, C-Tick, ICES, and FCC Part 15 Emissions; Class A
Note
For full EMC compliance, operate this device with shielded cabling.