![National Instruments MXI PXI Express Series User Manual Download Page 24](http://html1.mh-extra.com/html/national-instruments/mxi-pxi-express-series/mxi-pxi-express-series_user-manual_3481808024.webp)
Appendix A
Specifications
MXI-Express x16 for PXI Express Series User Manual
A-4
ni.com
NI PCIe-8388
Pollution Degree .....................................2
Maximum altitude...................................2,000 m
Indoor use only.
Operating Environment
Ambient temperature range ....................0 to 55 °C
(Tested in accordance
with IEC-60068-2-1 and
IEC-60068-2-2.)
Relative humidity range..........................10 to 90%, noncondensing
(Tested in accordance with
IEC-60068-2-56.)
Storage Environment
Ambient temperature range ....................–20 to 70 °C
(Tested in accordance
with IEC-60068-2-1 and
IEC-60068-2-2.)
Relative humidity range..........................5 to 95%, noncondensing
(Tested in accordance with
IEC-60068-2-56.)
Caution
Clean the NI PXIe-8388/9 and NI PCIe-8388 with a soft nonmetallic brush. Make
sure that the device is completely dry and free from contaminants before returning it to
service.
Safety
This product is designed to meet the requirements of the following
standards of safety for electrical equipment for measurement, control,
and laboratory use:
•
IEC 61010-1, EN 61010-1
•
UL 61010-1, CSA 61010-1
Note
For UL and other safety certifications, refer to the product label or the
section.