background image

MCA-7724 Motion Axis Router

2

ni.com

Connectivity Options

The controller connector on the MCA-7724 Motion Axis Router connects
to the 68-pin motion I/O connector on your controller. The adapter then
reroutes signals from the motion I/O connector to the accessory connectors
on the MCA-7724 Motion Axis Router. You can connect motion drives and
accessories in a 2 + 2 connectivity option or a 3 + 1 connectivity option.
Figures 2 and 3 show the two connectivity options.

Caution

Connect motion drives and accessories only to connectors A and B (2 + 2

connectivity option) or to connectors C and D (3 + 1 connectivity option). Failure to
connect the motion drives and accessories as shown in Figures 2 and 3 may result in
damage to the motion controller, axis router, drive, or accessory.

2 + 2 Connectivity Option

Controller axes 1 and 2 from the controller correspond to axes 1 and 2 on
connector A, and controller axes 3 and 4 correspond to axes 1 and 2 on
connector B, as shown in Figure 2.

Figure 2.

2 + 2 Connectivity Option

Controller

Connector

Connector

A

Connector

B

Axis 1 Signals

Axis 2 Signals

Shared Signals

Shared
Signals

Axis 3 Signals

Axis 4 Signals

Axis

1 Signals

Axis

2 Signals

Axis

3 Signals

Axis

4 Signals

Axis 1 Signals

Axis 2 Signals

Shared Signals

Shared Signals

Axis 1 Signals

Axis 2 Signals

T

o

Controller

T

o

Dr

iv

e/Accessor

y

T

o

Dr

iv

e/Accessor

y

Summary of Contents for Motion Axis Router MCA-7724

Page 1: ...he signals from your motion controller into separate connectors that connect to different motion accessories The router allows you to connect one two three and four axis drives and accessories to a co...

Page 2: ...nectors C and D 3 1 connectivity option Failure to connect the motion drives and accessories as shown in Figures 2 and 3 may result in damage to the motion controller axis router drive or accessory 2...

Page 3: ...e indicates that the signal is active low Per Axis Signals from the Controller Step CW Dir CCW Encoder Phase A Encoder Phase B Encoder Index Forward Limit Switch Reverse Limit Switch Home Switch Trigg...

Page 4: ...essory connectors Use caution to avoid double driving input signal shutdown Software Configuration Because of signal rerouting the axis number on your accessory may not match the programmed axis in yo...

Page 5: ...1 Home Switch Digital Ground Digital Ground Axis 1 Dir CCW Analog Input Ground Analog Input 2 Reserved Analog Output 2 Shutdown Breakpoint 4 Breakpoint 2 Analog Input 4 Analog Output 4 Host 5 V Axis...

Page 6: ...Home Switch Digital Ground Digital Ground Axis 1 Dir CCW Analog Input Ground Analog Input 2 Reserved Analog Output 2 Shutdown NC Breakpoint 2 NC NC Host 5 V NC NC NC NC NC NC NC NC NC NC NC NC Axis 2...

Page 7: ...gger 3 Axis 3 Home Switch Digital Ground Digital Ground Axis 3 Dir CCW Analog Input Ground Analog Input 4 Reserved Analog Output 4 Shutdown NC Breakpoint 4 NC NC Host 5 V NC NC NC NC NC NC NC NC NC NC...

Page 8: ...l Ground Digital Ground Axis 1 Dir CCW Analog Input Ground Analog Input 2 Reserved Analog Output 2 Shutdown NC Breakpoint 2 NC NC Host 5 V NC NC NC NC NC NC Axis 3 Reverse Limit Switch Axis 3 Forward...

Page 9: ...NC Digital Ground Digital Ground NC Axis 4 Inhibit Trigger 4 Axis 4 Home Switch Digital Ground Digital Ground Axis 4 Dir CCW Analog Input Ground NC Reserved NC Shutdown NC NC NC NC Host 5 V NC NC NC N...

Reviews: