background image

© 2014 National Instruments. All rights reserved. 

374810A-01

Sep14

Refer to the 

NI Trademarks and Logo Guidelines 

at 

ni.com/trademarks

 for more information on National Instruments trademarks. Other 

product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National 
Instruments products/technology, refer to the appropriate location: 

Help»Patents

 in your software, the 

patents.txt

 file on your media, or the 

National Instruments Patents Notice

 at 

ni.com/patents

. You can find information about end-user license agreements (EULAs) and third-party 

legal notices in the readme file for your NI product. Refer to the 

Export Compliance Information 

at 

ni.com/legal/export-compliance

 

for the National Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES 
NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR 
ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable 
limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015.

After the move has been stopped, errors are cleared and the motion reference is destroyed.

Figure 6.  

Destroying Move Reference

Worldwide Support and Services

The National Instruments website is your complete resource for technical support. At 

ni.com/

support

 you have access to everything from troubleshooting and application development 

self-help resources to email and phone assistance from NI Application Engineers.

Visit 

ni.com/services

 for NI Factory Installation Services, repairs, extended warranty, and 

other services.

Visit 

ni.com/register

 to register your National Instruments product. Product registration 

facilitates technical support and ensures that you receive important information updates from NI. 

A Declaration of Conformity (DoC) is our claim of compliance with the Council of the European 
Communities using the manufacturer’s declaration of conformity. This system affords the user 
protection for electromagnetic compatibility (EMC) and product safety. You can obtain the DoC 
for your product by visiting 

ni.com/certification

. If your product supports calibration, 

you can obtain the calibration certificate for your product at 

ni.com/calibration

.

National Instruments corporate headquarters is located at 11500 North Mopac Expressway, 
Austin, Texas, 78759-3504. National Instruments also has offices located around the world. For 
telephone support in the United States, create your service request at 

ni.com/support

 or dial 

1 866 ASK MYNI (275 6964). For telephone support outside the United States, visit the 
Worldwide Offices section of 

ni.com/niglobal

 to access the branch office websites, which 

provide up-to-date contact information, support phone numbers, email addresses, and current 
events.

Summary of Contents for ISM-7411

Page 1: ...tep 1 Connect the NI PS 12 13 Power Supply 3 Step 2 Connect the Integrated Stepper to the Network 4 Step 3 Verify the Connections 8 Using the ISM with SoftMotion 8 Running the Example 8 Understanding the Example 9 Worldwide Support and Services 10 What You Need to Get Started You need the following items to get started Hardware 12 VDC to 70 VDC power supply NI PS 12 NI part number 748906 01 or NI ...

Page 2: ...To access this help file from LabVIEW select Help LabVIEW Help then expand the LabVIEW NI SoftMotion Module book on the Contents tab LabVIEW Help Use the LabVIEW Help to access information about LabVIEW programming concepts step by step instructions for using LabVIEW and reference information about LabVIEW VIs functions palettes menus tools properties methods events dialog boxes and so on The LabV...

Page 3: ...f the V wire to the corresponding terminal on the included power connector Tighten the screw to ensure a secure connection 4 Connect one end of a 1 02 mm to 0 81 mm diameter 18 20 AWG gauge stranded wire to the V terminal on the power supply 5 Connect the free end of the V wire to the corresponding terminal on the included power connector Tighten the screw to ensure a secure connection 6 Insert th...

Page 4: ...ress for each switch setting is shown in the table below Settings 1 through E can be changed using the NI Stepper Configuration Utility software Setting 0 is always 10 10 10 10 the universal recovery address Setting F is DHCP which commands the device to get an IP address from a DHCP server on the network The IP address automatically assigned by the DHCP server may be dynamic or static depending o...

Page 5: ...mething else by the DHCP server at another time Once you ve chosen an appropriate IP address for your device set the rotary switch according to the address table above If none of the default addresses are acceptable for your network you can enter a new table of IP addresses using the NI Stepper Configuration Utility If your network uses addresses starting with 192 168 0 the most common subnet you ...

Page 6: ... Utility can find your device using the Drive Discovery feature as long as your network isn t too large When the device connected to the network is powered on select Drive Discovery from the Drive menu to launch the Network Interface Dialog dialog box Figure 3 Network Interface Dialog Box Normally Drive Discovery only detects one network interface card NIC and selects it automatically If you are u...

Page 7: ...e device s IP address to this interface card 6 Next enter the subnet mask as 255 255 255 0 7 Leave Default gateway blank This prevents your PC from looking for a router on this subnet Note Because you are connected directly to the device anytime the device is not powered you will receive a small message bubble in the corner of your screen saying The network cable is unplugged Option 3 Use Two Netw...

Page 8: ...ed stepper 3 Open the Drive menu and select Self Test 4 Click Start The motor should begin to move Click Stop to finish the test If the motor failed to move verify the power and network connections Examine the Status LED and refer to the integrated stepper user manual to diagnose any issues Using the ISM with SoftMotion The integrated stepper can be used in a LabVIEW VI as a standard motion resour...

Page 9: ... s2 When all the settings are configured run the VI and click the Start Move button The motor should turn according to the configured move Click the Stop Move button to stop the motor and the Stop VI when you are finished with the project Understanding the Example The example VI begins by creating a motion resource and using an invoke node to enable the drive Figure 4 Creating a Motion Resource Wh...

Page 10: ... Worldwide Support and Services The National Instruments website is your complete resource for technical support At ni com support you have access to everything from troubleshooting and application development self help resources to email and phone assistance from NI Application Engineers Visit ni com services for NI Factory Installation Services repairs extended warranty and other services Visit ...