Chapter 6
Using Your GPIB-ENET/100 and NI-488.2
GPIB-ENET/100 for Windows Me/98/95
6-6
ni.com
Note
The NI Ethernet Device Firmware Update utility cannot update the firmware while
any network connections are active. Close any open connections before you attempt a
firmware update. Hosts cannot connect to the GPIB-ENET/100 while it is updating the
firmware.
To start the Update Firmware utility, complete the following steps:
1.
Select
Start»Programs»National Instruments»NI-488.2»Explore
GPIB
to start the Measurement & Automation Explorer.
2.
Under
Measurement & Automation
, expand the
Devices and
Interfaces
folder.
3.
Right-click on the
GPIB-ENET/100
item and select
Update
Firmware
from the drop-down menu that appears.
Figure 6-2 shows the NI Ethernet Device Firmware Update utility.
Figure 6-2.
NI Ethernet Device Firmware Update Utility
4.
Enter the IP address or the hostname of the GPIB-ENET/100 in the
IP address or hostname
edit box. An example of an IP address is
137.65.220.40
. An example of a hostname is
myenet1
.
5.
Enter the full path of the binary file where the firmware is located in
the
EEPROM binary image filename
edit box. You also can click
Browse...
to locate the file.
6.
Click
Update
to update the firmware. The NI Ethernet Device
Firmware Update utility communicates with the specified
GPIB-ENET/100 to verify the box has no open network connections
and determine the current version of the firmware in the unit. A dialog
box reports that the update utility is searching for the Ethernet device.