Appendix D
Interactive Software Installation
© National Instruments Corp.
D-3
GPIB-PCII/IIA for Graphics
Running IBDIAG for MS-DOS
Upon completion of the software installation,
INSTALL
returns to the main
menu. Select
Diagnostics
to run the hardware diagnostic program,
IBDIAG
.
IBDIAG
confirms that the hardware is functioning properly, and
verifies that the software configuration settings are set correctly.
If
IBDIAG
returns an error message, check the GPIB-PCII/IIA to ensure
that it is not connected to a GPIB cable.
IBDIAG
may not function
properly if a cable is connected to the GPIB-PCII/IIA.
If
IBDIAG
still returns an error message, you may need to check the
hardware configuration switch and jumper settings. Refer to Appendix C,
Hardware and Software Configuration, for information on checking and
changing the GPIB-PCII/IIA hardware configuration settings.
If there are no errors,
INSTALL
displays the DOS installation menu.
Exiting INSTALL
You have completed the interactive version of
INSTALL
for
MS-DOS.
Select
Return
to
DOS
from the DOS installation menu to exit
INSTALL
.
Proceed to Step 2. Test the Software Installation in Chapter 3, Software
Installation, to complete the installation procedure.
INSTALL for Windows
Select
Windows
GPIB
Installation
from the main menu.
INSTALL
displays a Windows installation menu with three options:
Windows
Installation
,
Diagnostics
, and
Return
to
Windows
.
If you have already installed the NI-488.2 software files and need to run
IBDIAG
again, refer to Running IBDIAG for Windows, later in this section.