Configuration and Installation
Chapter 2
GPIB-232CV User Manual
2-2
© National Instruments Corp.
If your system has a GPIB Controller that is responsible for addressing the
GPIB-232CV to talk or listen, the GPIB-232CV should be set to operate in
the Device (D) mode. It is called the Device mode because the
GPIB-232CV functions like another GPIB device.
An example of a system operating in D mode is a RS-232 device, such as a
serial printer, connected to a GPIB system with an existing GPIB
Controller, such as an IBM PC with a National Instruments AT-GPIB
board, as shown in Figure 2-2.
IBM PC AT
(GPIB Controller)
GPIB Device
Serial
Cable
GPIB
Cables
GPIB-232CV
Printer
(Serial Device)
GPIB-422CV
IEEE 488
RS-422 CONVERTER
POWER
READY
TALK
LISTEN
BUSY
FULL
Figure 2-2. Example of D Mode System Setup
Installation
Install the GPIB-232CV according to the following procedure.
1.
Inspect the GPIB-232CV for damage that may have been caused in
shipment.
2.
Verify the voltage requirement.
3.
Configure the operating parameters.
4.
Connect the cables.
5.
Power on the unit.
Summary of Contents for GPIB-232CV