background image

Contents

© National Instruments Corporation

ix

GPIB-100A User Manual

Figures

Figure 1-1. The Model GPIB-100A Bus Extender..................................................................

 1-1

Figure 1-2. Typical GPIB-100A Extension System (Physical Configuration) ........................

 1-2

Figure 1-3. Typical GPIB-100A Extension System (Logical Configuration)..........................

 1-2

Figure 2-1. Voltage Selection....................................................................................................

 2-1

Figure 3-1. Switch Settings for Operating Mode ......................................................................

 3-2

Figure 3-2. Switch Settings for Parallel Poll Response Mode...................................................

 3-4

Figure 4-1. GPIB-100A Block Diagram...................................................................................

 4-1

Figure A-1. GPIB Cable Connector..........................................................................................

 A-3

Figure A-2. Linear Configuration of the GPIB Devices............................................................

 A-5

Figure A-3. Star Configuration of GPIB Devices.....................................................................

 A-6

Figure C-1. GPIB-100A Parts Locator Diagram......................................................................

 C-1

Tables

Table 1-1. System Configuration Characteristics......................................................................

 1-3

Table 1-2. Performance Characteristics.....................................................................................

 1-4

Table 1-3. Operating Characteristics .........................................................................................

 1-4

Table 1-4. Electrical Characteristics ..........................................................................................

 1-5

Table 1-5. Environmental Characteristics .................................................................................

 1-5

Table 1-6. Physical Characteristics............................................................................................

 1-6

Table 1-7. Components and Accessories..................................................................................

 1-6

Table D-1. Cable Assembly Wire List......................................................................................

 D-1

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Summary of Contents for GPIB-100

Page 1: ...erutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In st...

Page 2: ...5 1991 National Instruments Corporation All Rights Reserved GPIB 100A User Manual March 1990 Edition Part Number 320063 01 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www...

Page 3: ...ion 6504 Bridge Point Parkway Austin TX 78730 5039 512 794 0100 800 IEEE 488 toll free U S and Canada Technical support fax 512 794 5678 Artisan Technology Group Quality Instrumentation Guaranteed 888...

Page 4: ...LAR PURPOSE CUSTOMER S RIGHT TO RECOVER DAMAGES CAUSED BY FAULT OR NEGLIGENCE ON THE PART OF NATIONAL INSTRUMENTS SHALL BE LIMITED TO THE AMOUNT THERETOFORE PAID BY THE CUSTOMER NATIONAL INSTRUMENTS W...

Page 5: ...are much less if the equipment is used according to this instruction manual If the equipment does cause interference to radio or television reception which can be determined by turning the equipment o...

Page 6: ...100A circuitry operates Appendix A Operation of the GPIB describes GPIB terminology and protocol for users unfamiliar with the GPIB Appendix B Schematic Diagram contains a detailed schematic diagram o...

Page 7: ...ed in the text of this manual C centigrade F Fahrenheit Hz hertz in inch kbytes thousand bytes m meter mA milliamperes Mbytes million bytes mm millimeter sec microsecond nsec nanosecond sec second V v...

Page 8: ...Modes 3 1 Talker Listener Controller TLC Mode 3 1 Talker Listener TL Mode 3 2 Setting the Operating Mode 3 2 Parallel Poll Response PPR Modes 3 2 Buffered PPR Mode Approach 1 3 3 Unbuffered PPR Mode A...

Page 9: ...epted A 4 DAV data valid A 4 Interface Management Lines A 4 ATN attention A 4 IFC interface clear A 4 REN remote enable A 4 SRQ service request A 4 EOI end or identify A 4 Physical and Electrical Char...

Page 10: ...k Diagram 4 1 Figure A 1 GPIB Cable Connector A 3 Figure A 2 Linear Configuration of the GPIB Devices A 5 Figure A 3 Star Configuration of GPIB Devices A 6 Figure C 1 GPIB 100A Parts Locator Diagram C...

Page 11: ...ble length limit of 20 m total per contiguous bus or 2 m times the number of devices on the bus whichever is smaller Electrical loading limit of 15 devices per contiguous bus Each GPIB 100A system ext...

Page 12: ...agraph Parallel Poll Response PPR Modes GPIB 2 GPIB 1 GPIB 100A Computer System Controller Talker and Listener Printer Listener Multimeter Talker and Listener Signal Generator Listener Unit Under Test...

Page 13: ...ration Characteristics Characteristic Specification distance per extension up to 300 m loading per extension up to 14 additional devices multiple extensions permitted in any combination of star or lin...

Page 14: ...mplete Source Handshake identification AH1 complete Acceptor Handshake codes T5 TE5 complete Talker L3 LE3 complete Listener SR1 complete Service Request RL1 complete Remote Local PP1 2 complete Paral...

Page 15: ...s power supply 50 to 60 Hz selectable fuse 110 V 160 mA 250 mA 250 V Slow Blow 220 V 80 mA 200 mA 250 V Slow Blow GPIB interface load one standard load AC and DC power 18 W typical Table 1 5 Environme...

Page 16: ...with AMP Amplimite connectors AMP HDP 20 50 pin connector with RFI EMI shield Table 1 7 Components and Accessories Item Part Number Model GPIB 100A Bus Extender 110V 776107 01 two required per extens...

Page 17: ...y set at a certain operating voltage either 110 VAC or 220 VAC Verify that the voltage you are using is the same as that selected on the rear panel of the GPIB 100A Operating at a voltage other than t...

Page 18: ...ing The GPIB 100A enclosure is designed for table top operation or for rack mounting Single and dual unit rack mounting kits are available from National Instruments for field installation Connecting t...

Page 19: ...brief description of this mode is in the following paragraph Both units power up in a quiescent condition with no local or remote state active They remain that way until one unit detects an IFC pulse...

Page 20: ...press down Figure 3 1 Switch Settings for Operating Mode Parallel Poll Response PPR Modes According to ANSI IEEE Standard 488 l978 devices must respond to a parallel poll within 200 nsec after the Id...

Page 21: ...ollers contains an easy to use parallel poll function If for example the function is called PPOLL and the control program is written in BASIC the sequence to conduct a poll in Buffered PPR mode might...

Page 22: ...igure 3 2 Switch Settings for Parallel Poll Response Mode Operating the GPIB 100A System The GPIB 100A extension system is fully operational when power is applied to both units In TLC mode it is somet...

Page 23: ...100A parts locator diagram Figure 4 1 GPIB 100A Block Diagram Power On When the GPIB 100A is powered on a reset pulse PON created by U48F U28A D and associated Register Capacitor Delay RCD network di...

Page 24: ...LAC FF to be set if ATN is already asserted when IFC occurs When ATN is received from the local side via transceiver U2C the LAC FF is set on the leading edge of ATN and after a delay through U11B C D...

Page 25: ...GPIB transceiver U1B and NRFD is transmitted to the other side through driver U30A XRFD Once the LS FF is set the propagation of NRFD from the remote side sets FF U36A via receiver U19A U44C and U35A...

Page 26: ...are driven is the remote unit through receivers U15 and U17 when Unbuffered PPR mode is selected Switch S1 position 3 open or when the RS FF is set and a remote parallel poll is not in progress U47A a...

Page 27: ...es manage the bus itself They are usually called commands or command messages Interface messages perform such functions as initializing the bus addressing and unaddressing devices and setting devices...

Page 28: ...ler For example one device may only be a Talker called a Talk only device and there may be one or more Listen only devices A Controller is necessary when the active or addressed Talker or Listener mus...

Page 29: ...command messages All commands and most data use the 7 bit ASCII or ISO code set in which case the eighth bit DIO8 is unused or used for parity Appendix E lists the GPIB command messages Handshake Lin...

Page 30: ...nes are used to manage the flow of information across the interface ATN attention The Controller drives ATN true when it uses the data lines to send commands and false when it allows a Talker to send...

Page 31: ...sembly consisting of a shielded 24 conductor cable with both a plug and receptacle at each end This design allows devices to be connected in either a linear or a star configuration or a combination of...

Page 32: ...MICRORIBBON or AMP CHAMP type An adapter cable using non standard cable and or connector is used for special interconnect applications The GPIB uses negative logic with standard TTL logic levels When...

Page 33: ...o be connected to the bus and 20 meters of cable length to be added to the system National Instruments provides two extenders which allow longer cable spans These products are the GPIB 100A and the GP...

Page 34: ...Corporation B 1 GPIB 100A User Manual Appendix B Schematic Diagram This appendix contains the schematic diagram for the GPIB 100A Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOU...

Page 35: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 36: ...m This appendix contains the parts locator diagram for the GPIB 100A The parts locator diagram shows the locations of the GPIB 100A configuration jumpers and switches Figure C 1 GPIB 100A Parts Locato...

Page 37: ...on D 1 GPIB 100A User Manual Appendix D Cable Assembly Wire List This appendix contains the wire list for the GPIB 100A Transmission Cable Artisan Technology Group Quality Instrumentation Guaranteed 8...

Page 38: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 39: ...100A User Manual Appendix E Multiline Interface Command Messages The following tables are multiline interface messages sent and received with ATN TRUE Artisan Technology Group Quality Instrumentation...

Page 40: ...2F 057 47 MLA15 10 020 16 DLE 30 060 48 0 MLA16 11 021 17 DC1 LLO 31 061 49 1 MLA17 12 022 18 DC2 32 062 50 2 MLA18 13 023 19 DC3 33 063 51 3 MLA19 14 024 20 DC4 DCL 34 064 52 4 MLA20 15 025 21 NAK PP...

Page 41: ...6 110 n MSA14 PPE 4F 117 79 O MTA15 6F 157 111 o MSA15 PPE 50 120 80 P MTA16 70 160 112 p MSA16 PPD 51 121 81 Q MTA17 71 161 113 q MSA17 PPD 52 122 82 R MTA18 72 162 114 r MSA18 PPD 53 123 83 S MTA19...

Page 42: ...Valid DIO Data EOI End or Identify Bit FF Flip flop IDY Identify IFC Interface Clear ISO International Standard code set L Listener LAC Local Active Controller LS Local Source LSC Local System Contro...

Page 43: ...ote Enable RFD Ready for Data RR Remote Response RS Remote Source RSC Remote System Controller SRQ Service Request T Talker TL Talker Listener TLC Talker Listener Controller GPIB Adapter TTL Transisto...

Page 44: ...er 320063 01 Please comment on the completeness clarity and organization of the manual If you find errors in the manual please record the page numbers and describe the errors Thank you for your help N...

Page 45: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Reviews: