FP-DIO-550 and cFP-DIO-550
4
ni.com
Install a 2 A maximum, fast-acting fuse between the external
power supply and the V terminals. The wiring diagrams in this
document show fuses where appropriate.
Table 1.
Input Terminal Assignments
Channel
Terminal Numbers
IN+
IN–
In 0
1
2
In 1
3
4
In 2
5
6
In 3
7
8
In 4
17
18
In 5
19
20
In 6
21
22
In 7
23
24
Table 2.
Output Terminal Assignments
Channel
Terminal Numbers
V
OUT
COM
Out 0
9
10
Out 1
11
12
Out 2
13
14
Out 3
15
16
Out 4
25
26
Out 5
27
28
Out 6
29
30
Out 7
31
32
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com