![background image](http://html1.mh-extra.com/html/national-instruments/ettus-e3-series/ettus-e3-series_getting-started-manual_3436056017.webp)
Ettus E3XX Getting Started Guide
ANGRYVIPER Team
9.2
Run an Application in Standalone Mode
The default setup script sets the
OCPI_LIBRARY_PATH
variable to include the all of the artifacts that are required to
execute the application. Specifically, all three of the artifacts that are located on the SD card are mounted at
/mnt/card/opencpi/xilinx13_4/artifacts
. After running
mysetup.sh
, navigate to
/mnt/card/opencpi/xml
.
Run the application using the following command:
$ ocpirun -v -t 1 -d -m bias=hdl bias.xml
The output should be similar to the output shown in Section 9.1.
Run the following commands to view the input and output, and reference Section 9.1 for the expected results:
$ hexdump test.input | less
$ hexdump test.output | less
10
Running Reference Applications
Now that you have set up OpenCPI and the E310 radio, you can run one of the reference applications. Navigate to
bsp_e310/applications/FSK
or
bsp_e310/applications/rx_app
and follow the instructions in the corresponding
documents (
FSK_App_Getting_Started_Guide_E3XX.pdf
and
FSK_app_e3xx.pdf
, or
RX_app_e3xx.pdf
).
17