Appendix B
Register Information
DAQ-STC Technical Reference Manual
B-10
©
National Instruments Corporation
Register Maps
AI_Command_1_Register
Address: 8
Type: Write-only
15
Reserved
14
AI_Analog_Trigger_Reset
13
AI_Disarm
12
AI_SI2_Arm
11
AI_SI2_Load
10
AI_SI_Arm
9
AI_SI_Load
8
AI_DIV_Arm
7
AI_DIV_Load
6
AI_SC_Arm
5
AI_SC_Load
4
AI_SCAN_IN_PROG_Pulse
3
AI_EXTMUX_CLK_Pulse
2
AI_LOCALMUX_CLK_Pulse
1
AI_SC_TC_Pulse
0
AI_CONVERT_Pulse
AI_Command_2_Register
Address: 4
Type: Write-only
15
AI_End_On_SC_TC
14
AI_End_On_End_Of_Scan
13
Reserved
12
Reserved
11
AI_START1_Disable
10
AI_SC_Save_Trace
9
AI_SI_Switch_Load_On_SC_TC
8
AI_SI_Switch_Load_On_STOP
7
AI_SI_Switch_Load_On_TC
6
Reserved
5
Reserved
4
AI_SC_Switch_Load_On_TC
3
AI_STOP_Pulse
2
AI_START_Pulse
1
AI_START2_Pulse
0
AI_START1_Pulse