Chapter 2
Analog Input Timing/Control
DAQ-STC Technical Reference Manual
2-96
©
National Instruments Corporation
Figure 2-25.
External Trigger Timing, Synchronous Level, External CONVERT Mode
Figure 2-26.
External Trigger Timing, Synchronous Edge, External CONVERT Mode
Table 2-5.
External Analog Input Timing
Name
Description
Minimum
Maximum
Ts_strt1
START1 setup to CONVERT_SRC
33 (36)
—
Tstrt1
START1 pulsewidth (edge mode)
6
—
Th_strt1
START1 hold from CONVERT_SRC
(level mode)
4
—
Ts_strt2
START2 setup to CONVERT_SRC
31 (34)
—
Tstrt2
START2 pulsewidth (edge mode)
6
—
Th_strt2
START2 hold from CONVERT_SRC
(level mode)
4
—
Ts_strt
START setup to CONVERT_SRC
29 (32)
—
CONVERT_SRC
START1
START2
START
STOP
Ts_strt1
Th_strt1
Th_strt2
Th_strt
Th_stop
Ts_strt2
Ts_strt
Ts_stop
SI2 Source
START1
START2
START
STOP
Ts_strt1
Tstrt1
Tstrt2
Tstrt
Tstop
Ts_strt2
Ts_strt
Ts_stop