National Instruments DAQ M Series User Manual Download Page 3

 

Important Information

Warranty

The NI USB-6210, NI USB-6211, NI USB-6212, NI USB-6215, NI USB-6216, and NI USB-6218 are warranted against defects in materials 
and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other doc

u

mentation. National Instr

u

ments 

will, at its option, repair or replace eq

u

ipment that proves to be defective d

u

ring the warranty period. This warranty incl

u

des parts and labor. 

The media on which yo

u

 receive National Instr

u

ments software are warranted not to fail to exec

u

te programming instr

u

ctions, d

u

e to defects in 

materials and workmanship, for a period of 90 days from date of shipment, as evidenced by receipts or other doc

u

mentation. National Instr

u

ments 

will, at its option, repair or replace software media that do not exec

u

te programming instr

u

ctions if National Instr

u

ments receives notice of s

u

ch defects 

d

u

ring the warranty period. National Instr

u

ments does not warrant that the operation of the software shall be 

u

ninterr

u

pted or error free.

A Ret

u

rn Material A

u

thorization (RMA) n

u

mber m

u

st be obtained from the factory and clearly marked on the o

u

tside of the package before any 

eq

u

ipment will be accepted for warranty work. National Instr

u

ments will pay the shipping costs of ret

u

rning to the owner parts which are covered by 

warranty.

National Instr

u

ments believes that the information in this doc

u

ment is acc

u

rate. The doc

u

ment has been caref

u

lly reviewed for technical acc

u

racy. In 

the event that technical or typographical errors exist, National Instr

u

ments reserves the right to make changes to s

u

bseq

u

ent editions of this doc

u

ment 

witho

u

t prior notice to holders of this edition. The reader sho

u

ld cons

u

lt National Instr

u

ments if errors are s

u

spected. In no event shall National 

Instr

u

ments be liable for any damages arising o

u

t of or related to this doc

u

ment or the information contained in it.

E

XCEPT

 

AS

 

SPECIFIED

 

HEREIN

, N

ATIONAL

 I

NSTRUMENTS

 

MAKES

 

NO

 

WARRANTIES

EXPRESS

 

OR

 

IMPLIED

AND

 

SPECIFICALLY

 

DISCLAIMS

 

ANY

 

WARRANTY

 

OF

 

MERCHANTABILITY

 

OR

 

FITNESS

 

FOR

 

A

 

PARTICULAR

 

PURPOSE

. C

USTOMER

S

 

RIGHT

 

TO

 

RECOVER

 

DAMAGES

 

CAUSED

 

BY

 

FAULT

 

OR

 

NEGLIGENCE

 

ON

 

THE

 

PART

 

OF

 N

ATIONAL

 

I

NSTRUMENTS

 

SHALL

 

BE

 

LIMITED

 

TO

 

THE

 

AMOUNT

 

THERETOFORE

 

PAID

 

BY

 

THE

 

CUSTOMER

. N

ATIONAL

 I

NSTRUMENTS

 

WILL

 

NOT

 

BE

 

LIABLE

 

FOR

 

DAMAGES

 

RESULTING

 

FROM

 

LOSS

 

OF

 

DATA

PROFITS

USE

 

OF

 

PRODUCTS

OR

 

INCIDENTAL

 

OR

 

CONSEQUENTIAL

 

DAMAGES

EVEN

 

IF

 

ADVISED

 

OF

 

THE

 

POSSIBILITY

 

THEREOF

. This limitation of 

the liability of National Instr

u

ments will apply regardless of the form of action, whether in contract or tort, incl

u

ding negligence. Any action against 

National Instr

u

ments m

u

st be bro

u

ght within one year after the ca

u

se of action accr

u

es. National Instr

u

ments shall not be liable for any delay in 

performance d

u

e to ca

u

ses beyond its reasonable control. The warranty provided herein does not cover damages, defects, malf

u

nctions, or service 

fail

u

res ca

u

sed by owner’s fail

u

re to follow the National Instr

u

ments installation, operation, or maintenance instr

u

ctions; owner’s modification of the 

prod

u

ct; owner’s ab

u

se, mis

u

se, or negligent acts; and power fail

u

re or s

u

rges, fire, flood, accident, actions of third parties, or other events o

u

tside 

reasonable control.

Copyright

Under the copyright laws, this p

u

blication may not be reprod

u

ced or transmitted in any form, electronic or mechanical, incl

u

ding photocopying, 

recording, storing in an information retrieval system, or translating, in whole or in part, witho

u

t the prior written consent of National 

Instr

u

ments Corporation.

National Instr

u

ments respects the intellect

u

al property of others, and we ask o

u

u

sers to do the same. NI software is protected by copyright and other 

intellect

u

al property laws. Where NI software may be 

u

sed to reprod

u

ce software or other materials belonging to others, yo

u

 may 

u

se NI software only 

to reprod

u

ce materials that yo

u

 may reprod

u

ce in accordance with the terms of any applicable license or other legal restriction.

Trademarks

National Instr

u

ments, NI, ni.com, and LabVIEW are trademarks of National Instr

u

ments Corporation. Refer to the 

Terms of Use

 section 

on

ni.com/legal

 for more information abo

u

t National Instr

u

ments trademarks.

Other prod

u

ct and company names mentioned herein are trademarks or trade names of their respective companies.

Members of the National Instr

u

ments Alliance Partner Program are b

u

siness entities independent from National Instr

u

ments and have no agency, 

partnership, or joint-vent

u

re relationship with National Instr

u

ments.

Patents

For patents covering National Instr

u

ments prod

u

cts/technology, refer to the appropriate location: 

Help»Patents

 in yo

u

r software, 

the

patent

s

.txt

 file on yo

u

r media, or the 

National Instruments Patent Notice

 at 

ni.com/patent

s

.

WARNING REGARDING USE OF NATIONAL INSTRUMENTS PRODUCTS

(1) NATIONAL INSTRUMENTS PRODUCTS ARE NOT DESIGNED WITH COMPONENTS AND TESTING FOR A LEVEL OF 
RELIABILITY SUITABLE FOR USE IN OR IN CONNECTION WITH SURGICAL IMPLANTS OR AS CRITICAL COMPONENTS IN 
ANY LIFE SUPPORT SYSTEMS WHOSE FAILURE TO PERFORM CAN REASONABLY BE EXPECTED TO CAUSE SIGNIFICANT 
INJURY TO A HUMAN.

(2) IN ANY APPLICATION, INCLUDING THE ABOVE, RELIABILITY OF OPERATION OF THE SOFTWARE PRODUCTS CAN BE 
IMPAIRED BY ADVERSE FACTORS, INCLUDING BUT NOT LIMITED TO FLUCTUATIONS IN ELECTRICAL POWER SUPPLY, 
COMPUTER HARDWARE MALFUNCTIONS, COMPUTER OPERATING SYSTEM SOFTWARE FITNESS, FITNESS OF COMPILERS 
AND DEVELOPMENT SOFTWARE USED TO DEVELOP AN APPLICATION, INSTALLATION ERRORS, SOFTWARE AND HARDWARE 
COMPATIBILITY PROBLEMS, MALFUNCTIONS OR FAILURES OF ELECTRONIC MONITORING OR CONTROL DEVICES, 
TRANSIENT FAILURES OF ELECTRONIC SYSTEMS (HARDWARE AND/OR SOFTWARE), UNANTICIPATED USES OR MISUSES, OR 
ERRORS ON THE PART OF THE USER OR APPLICATIONS DESIGNER (ADVERSE FACTORS SUCH AS THESE ARE HEREAFTER 
COLLECTIVELY TERMED “SYSTEM FAILURES”). ANY APPLICATION WHERE A SYSTEM FAILURE WOULD CREATE A RISK OF 
HARM TO PROPERTY OR PERSONS (INCLUDING THE RISK OF BODILY INJURY AND DEATH) SHOULD NOT BE RELIANT SOLELY 
UPON ONE FORM OF ELECTRONIC SYSTEM DUE TO THE RISK OF SYSTEM FAILURE. TO AVOID DAMAGE, INJURY, OR DEATH, 
THE USER OR APPLICATION DESIGNER MUST TAKE REASONABLY PRUDENT STEPS TO PROTECT AGAINST SYSTEM FAILURES, 
INCLUDING BUT NOT LIMITED TO BACK-UP OR SHUT DOWN MECHANISMS. BECAUSE EACH END-USER SYSTEM IS 
CUSTOMIZED AND DIFFERS FROM NATIONAL INSTRUMENTS' TESTING PLATFORMS AND BECAUSE A USER OR APPLICATION 
DESIGNER MAY USE NATIONAL INSTRUMENTS PRODUCTS IN COMBINATION WITH OTHER PRODUCTS IN A MANNER NOT 
EVALUATED OR CONTEMPLATED BY NATIONAL INSTRUMENTS, THE USER OR APPLICATION DESIGNER IS ULTIMATELY 
RESPONSIBLE FOR VERIFYING AND VALIDATING THE SUITABILITY OF NATIONAL INSTRUMENTS PRODUCTS WHENEVER 
NATIONAL INSTRUMENTS PRODUCTS ARE INCORPORATED IN A SYSTEM OR APPLICATION, INCLUDING, WITHOUT 
LIMITATION, THE APPROPRIATE DESIGN, PROCESS AND SAFETY LEVEL OF SUCH SYSTEM OR APPLICATION.

Summary of Contents for DAQ M Series

Page 1: ...DAQ M Series NI USB 621x User Manual Bus Powered M Series USB Devices NI USB 621x User Manual ni com manuals Deutsch Français April 2009 371931F 01 ...

Page 2: ...ebanon 961 0 1 33 28 28 Malaysia 1800 887710 Mexico 01 800 010 0793 Netherlands 31 0 348 433 466 New Zealand 0800 553 322 Norway 47 0 66 90 76 60 Poland 48 22 328 90 10 Portugal 351 210 311 210 Russia 7 495 783 6851 Singapore 1800 226 5886 Slovenia 386 3 425 42 00 South Africa 27 0 11 805 8197 Spain 34 91 640 0085 Sweden 46 0 8 587 895 00 Switzerland 41 56 2005151 Taiwan 886 02 2377 2222 Thailand ...

Page 3: ... including photocopying recording storing in an information retrieval system or translating in whole or in part without the prior written consent of National Instruments Corporation National Instruments respects the intellectual property of others and we ask our users to do the same NI software is protected by copyright and other intellectual property laws Where NI software may be used to reproduc...

Page 4: ... Pinouts 1 2 Device Specifications 1 2 Applying Signal Labels to the USB 621x 1 3 USB Cable Strain Relief 1 4 Mounting the USB 621x 1 6 Desktop Use 1 6 DIN Rail Mounting 1 6 Panel Mounting 1 7 USB Device Security Cable Slot 1 8 Chapter 2 DAQ System Overview DAQ Hardware 2 1 DAQ STC2 2 2 Calibration Circuitry 2 2 Signal Conditioning 2 3 Sensors and Transducers 2 3 Cables and Accessories 2 4 USB 621...

Page 5: ...s 4 11 AI Sample Clock Signal 4 14 Using an Internal Source 4 14 Using an External Source 4 14 Routing AI Sample Clock to an Output Terminal 4 14 Other Timing Requirements 4 14 AI Sample Clock Timebase Signal 4 15 AI Convert Clock Signal 4 16 Using an Internal Source 4 16 Using an External Source 4 16 Routing AI Convert Clock to an Output Terminal 4 16 Using a Delay from Sample Clock to Convert Cl...

Page 6: ...renced Signal Sources 4 31 When to Use Differential Connections with Ground Referenced Signal Sources 4 32 When to Use Non Referenced Single Ended Connections with Ground Referenced Signal Sources 4 32 When to Use Referenced Single Ended Connections with Ground Referenced Signal Sources 4 33 Using Differential Connections for Ground Referenced Signal Sources 4 34 Using Non Referenced Single Ended ...

Page 7: ...onnecting Digital I O Signals on USB 6210 6211 6215 6218 Devices 6 3 Getting Started with DIO Applications in Software on USB 6210 6211 6215 6218 Devices 6 4 Digital I O on USB 6212 6216 Devices 6 4 Static DIO on USB 6212 6216 Devices 6 5 I O Protection on USB 6212 6216 Devices 6 5 Programmable Power Up States on USB 6212 6216 Devices 6 6 Increasing Current Drive on USB 6212 6216 Devices 6 6 Conne...

Page 8: ...nt 8 15 Measurements Using Quadrature Encoders 8 16 Measurements Using Two Pulse Encoders 8 18 Buffered Sample Clock Position Measurement 8 18 Two Signal Edge Separation Measurement 8 19 Single Two Signal Edge Separation Measurement 8 20 Buffered Two Signal Edge Separation Measurement 8 20 Counter Output Applications 8 21 Simple Pulse Generation 8 21 Single Pulse Generation 8 21 Single Pulse Gener...

Page 9: ...equency Output Signal 8 31 Routing Frequency Output to a Terminal 8 31 Default Counter Timer Pinouts 8 32 Counter Triggering 8 33 Other Counter Features 8 34 Sample Clock 8 34 Cascading Counters 8 35 Counter Filters 8 35 Prescaling 8 36 Duplicate Count Prevention 8 37 Example Application That Works Correctly No Duplicate Counting 8 37 Example Application That Works Incorrectly Duplicate Counting 8...

Page 10: ...eam 11 1 Data Transfer Methods 11 1 Changing Data Transfer Methods 11 2 Chapter 12 Triggering Triggering with a Digital Source 12 1 Appendix A Device Specific Information USB 6210 A 2 USB 6211 6215 A 4 USB 6212 6216 Screw Terminal A 6 USB 6212 6216 Mass Termination A 8 USB 6212 6216 BNC A 13 USB 6218 Screw Terminal A 19 USB 6218 BNC A 21 Appendix B Troubleshooting Appendix C Technical Support and ...

Page 11: ...ut A 2 Figure A 2 USB 6211 6215 Pinout A 4 Figure A 3 USB 6212 6216 Screw Terminal Pinout A 6 Figure A 4 USB 6212 6216 Mass Termination Pinout A 9 Figure A 5 USB 6212 6216 BNC Top Panel and Pinout A 14 Figure A 13 USB 6218 Screw Terminal Pinout A 19 Figure A 14 USB 6218 BNC Top Panel and Pinout A 22 ...

Page 12: ... The symbol leads you through nested menu items and dialog box options to a final action The sequence File Page Setup Options directs you to pull down the File menu select the Page Setup item and select Options from the last dialog box This icon denotes a note which alerts you to important information This icon denotes a caution which advises you of precautions to take to avoid injury data loss or...

Page 13: ...DAQmx for USB Devices Getting Started Guide describes how to install your NI DAQmx for Windows software your NI DAQmx supported DAQ device and how to confirm that your device is operating properly Select Start All Programs National Instruments NI DAQ NI DAQmx for USB Devices Getting Started The NI DAQ Readme lists which devices are supported by this version of NI DAQ Select Start All Programs Nati...

Page 14: ...rence Help contains C reference and general information about measurement concepts In Windows select Start All Programs National Instruments NI DAQmx Base Documentation C Function Reference Help Note All NI DAQmx Base documentation for Linux is installed at usr local natinst nidaqmxbase documentation Note All NI DAQmx Base documentation for Mac OS X is installed at Applications National Instrument...

Page 15: ...ains measurement concepts for NI DAQmx This book also contains Taking an NI DAQmx Measurement in LabWindows CVI which includes step by step instructions about creating a measurement task using the DAQ Assistant In LabWindows CVI select Help Contents then select Using LabWindows CVI Data Acquisition The NI DAQmx Library book of the LabWindows CVI Help contains API overviews and function reference f...

Page 16: ...al Instruments data acquisition devices to develop instrumentation acquisition and control applications Select Start All Programs National Instruments NI DAQ NI DAQmx C Reference Help NET Languages without NI Application Software With the Microsoft NET Framework version 1 1 or later you can use NI DAQmx to create applications using Visual C and Visual Basic NET without Measurement Studio You need ...

Page 17: ...ice Documentation directory and double click the Device Documents shortcut for your language to find view and print device documents Training Courses If you need more help getting started developing an application with NI products NI offers training courses To enroll in a course or obtain a detailed course outline refer to ni com training Technical Support on the Web For additional support refer t...

Page 18: ...ide which you can download from ni com manuals offers NI DAQmx users step by step instructions for installing software and hardware configuring channels and tasks and getting started developing an application Installing Other Software If you are using other software refer to the installation instructions that accompany your software Installing the Hardware The NI DAQmx for USB Devices Getting Star...

Page 19: ...alibration using Measurement Automation Explorer MAX by completing the following steps 1 Launch MAX 2 Select My System Devices and Interfaces NI DAQmx Devices your device 3 Initiate self calibration using one of the following methods Click Self Calibrate in the upper right corner of MAX Right click the name of the device in the MAX configuration tree and select Self Calibrate from the drop down me...

Page 20: ... labels with pin numbers or signal names or blank labels Choose one of the labels align the correct label with the terminals printed on the top panel of your device or the 16 position combicon connector and apply the label as shown in Figure 1 1 Figure 1 1 USB 621x Screw Terminal Signal Labels 1 Terminal Number Label 2 Single Ended Signal Name Label 3 Differential Signal Name Label 4 User Defined ...